background image

A Division of HMC Enterprises LLC • 

2501 Grant Avenue • Philadelphia, PA  19114 USA

(215) 464-6800 • 1-800-344-8222 • Fax (215) 969-4890 • E-Mail: [email protected] • www.howardmccray.com

32E Series – Endless Design

Curved Glass – Single Duty – Deli

Technical Data

SHIPPING INFORMATION

Model #

Self contained

SC-CDS32E-4C-LS SC-CDS32E-6C-LS SC-CDS32E-8C-LS

Remote

R-CDS32E-4C-LS R-CDS32E-6C-LS

R-CDS32E-8C-LS

50"
48"
50-1/2"
50"
30-1/2"
30"
YES

74"
72"
50-1/2"
50"
30-1/2"
30"
YES

98"
96"
50-1/2"
50"
30-1/2"
30"
YES

Length with (2) ends
Length without ends
Height with ends
Height without ends
Depth with ends
Depth without ends
Endless design
(Dimensions are +/- 1/4")

White
Stainless Polish
Stainless Bright
Anodized
2
20-1/2"X23-1/2"
1
No
Curved
2
23-5/8"X25"
23
Standard

White
Stainless Polish
Stainless Bright
Anodized
2
31"X23-1/2"
1
No
Curved

23-5/8"X25"
34.5
Standard

White
Stainless Polish
Stainless Bright
Anodized
4
20-1/2"X23-1/2"
1
No
Curved
4
23-5/8"X25"
46
Standard

Exterior color
Interior color
Inside end panels
Floors
# of top doors
Door size
# of coils
Bottom storage
Front Glass
# of main deck shelves
Main deck size
Cubic capacity 

(

ft

3

)

Mezzanine, 1 row lighted

36°F

to 

40°F

R134a
1/4

30
12
1 per day
1400
115V
6.6A
1.4A
No

36°F

to 

40°F

R134a
1/3

30
12
1 per day
2100
115V
9.7A
2.2A
No

36°F

to 

40°F

R134a
1/2

30
12
1 per day
2800
115V
12.4A
2.8A
No

Operating temperature
Refrigerant (expansion valve)
Compressor size HP

Pressure control settings @
75°F, 55%RH

Defrost per day (24 hours)

BTU’s at +20°F Evap. Temp.

Voltage
Amperage
Amperage, lights only
Cord and plug

Self contained
Self contained

CUT IN

CUT OUT

Air Defrost
Remote

Self contained
Remote

55"
44"
61"
500#
460#
85ft

3

55"
44"
87"
710#
660#
122ft

3

55"
44"
115"
940#
910#
161ft

3

Height
Depth
Length
Gross weight

Cubic feet

Self contained
Remote

• Cases are designed to operate at 75 degrees Fahrenheit and 55% relative humidity
• Cases are equipped with drains; check your local building codes for connection requirements.
• Specification subject to change without notice

Отзывы: