Intended Use and Precautions
INDICATIONS FOR USE
Assist patients who are unable to turn or laterally position themselves.
Use as a Post-Prone Positioning Device in leu of pillows, foam, or gel
positioners.
Assist patients to sit on the edge of the bed.
CONTRAINDICATIONS
Patients who are experiencing thoracic, cervical or lumbar fractures
that are deemed unstable.
INTENDED CARE SETTINGS
Hospitals, long-term or extended care facilities.
PRECAUTIONS
• Ensure the Q
2
Roller meets the patient’s needs and use clinical
judgement in using the Q2Roller.
• It is recommended to use a minimum of two caregivers when
operating the Q
2
Roller. However, one caregiver may operate
the Q2Roller if side rails are raised.
• Ensure valves are not in contact with the patient while on the Q
2
Roller.
• Product is single-patient use and should only be used by trained
personnel.
• Only use attachments and/or accessories that are authorized
by HoverTech International.
• Use the Q
2
Roller according to instructions.
• Only for use with the HT-Air air supply adjustable button.
• Make sure patient is centered on the Q
2
Roller before inflating using
the Reference Center Line Indicator on the Q
2
Roller.
• Caregivers must ensure patient is attended and stabilized during
Q
2
Roller inflation, deflation or when inflated at angles greater than
30 degrees.
• Do not launder.
• Reference product-specific user manuals for additional operating
instructions.
PRECAUTIONS – HOVERTECH INTERNATIONAL
AIR SUPPLY
• Route the power cord in a manner to ensure freedom from hazard.
• Avoid blocking the air intakes of the air supply.
• Use this product only for its intended purpose as described in this
manual.
• CAUTION: Avoid electric shock. Do not open air supply.
Part Identification - Q
2
Roller
Center Line Indicator
Black Inflation Valve (2)
Red Deflation Valve (2)
Turning Chambers
Securing Apron
Air Intake
Filter Cover
Hose
Nozzle
Hose
Hose Release Button
Control Panel Label
Carrying Handle/
Attachment Hook
Power
Cord
Strap
Power
Cord
WARNING: The HT-Air is not compatible with DC power supplies.
The HT-Air is not intended for use with the HoverJack Battery Cart.
CAUTION: NO USER SERVICEABLE PARTS.
Only qualified service personnel shall perform repairs on the
HoverTech International Air Supply.