8
2.3
Assembly of the panelling
Fig. 1
Attach the cable channels (2, Fig. 06) left and right
to the pins and fix with the central hexagon nuts and
washers (3a) already mounted to the boiler.
Fig. 2
Attach the side walls (4, Fig. 06) to the boiler and
fix with the hexagon nuts and washers (4a) already
mounted to the boiler. Hook the side wall side onto
the screw head on the condensate drip tray at the
bot tom. Align the side walls centrally. Adjust the free
space for electrical box and rear wall. Then tighten
the hexag on nuts (4a).
Fig. 3
Attach rear wall (terminal plate 5, Fig. 07) of the ter
-
minal box using the 4 screws (5a).
Fig. 4
Remove stud (6, Fig. 07) on the left or right. Hook
the terminal box (6a) in at the bottom, on the side
where the stud is located. Hold the terminal box in
horizontal position and tighten in position with the
second stud on the opposite side. Fold the terminal
box shut towards the top and hook it in.
Fig. 5
-
open terminal box to fit the top screw (7a, Fig. 09)
-
close terminal box again to fit the bottom screw (7b,
Fig. 6
Route cables and establish plug-in connections
(wiring in accordance with Fig. 11).
Insert capillaries
with the immersion sensors (4a, Fig. 11) into the im
-
mersion sleeve (4b, Fig. 10) and attach using retain
-
ing spring (4c, Fig. 10).
Route capillary of the flue gas
safety temperature limiter (4d, Fig. 11) to the rear, to
the flue gas pipe. Drill a hole of Ø 11.5 mm in the flue
gas con duit (on-site) and attach the sensor of the flue
gas safety temperature limiter using a Viton plug.
CAUTION
Make sure that the cable does
not touch any hot locations!
Fig. 7
Drill a hole in the flue gas pipe (on site; 1, Fig. 03)
-
Ø 11.5 mm,for a thin-walled steel pipe
-
Ø 12.5 mm for a thick-walled pipe, e.g. made of plastic
1
2
Fig. 03
Fig. 8Fit the rubber stopper (2, Fig. 03) into the hole.
Fig. 04
Fig. 9Coat the sensor element with assembly lubricant
and insert the pressed part into the rubber stopper.
Fig. 05
Fig. 10Attach the lower rear wall (8, Fig. 11) to the side
walls. Mutually attach the rear walls (8a, 8b) and en
-
gage together at the side walls.
Fit the burner before installing the absorber
Fig. 11
Fit top side walls (9a, 9b, Fig. 11). Position the
lower edge of the top side walls (longitudinal bore
hole) on the special screws of the bottom side walls
and slide them in. Attach top side walls using 4 self-
tapping screws (9c) ø 3.5 x 10.
Fig. 12
Attach upper rear walls (10, Fig. 11)
Fig. 13
Put on cover plates (11, Fig. 11). Fit top front (11a),
position pins in slots and slide towards the rear. (When
removing, lift first one side, then the other side).
Fig. 14
Hook the front cover in (12, Fig. 11) at the bottom
and slide shut at the top. Attach with lateral locking
bolt (12a) (turn approx. ¼ turn to the right).
Fig. 15
The remaining 3 casing walls (14, 14a, 15, Fig. 13)
are attached after mounting the condensate boxes.
4 213 787 / 01