8.7.
Error codes on the thermostat LCD
Error codes are displayed next to the flashing icons
y i
.
8.8.
Error codes for the receiver
Error
code
Failure cause
Corrective action
1È
Broken external
temperature sensor.
Contact your local dealer.
LED
Failure cause
Corrective action
Green
!
LED
slowly blinking
There is no longer
communication
between the
receiver and the
thermostat. Both
heating and cooling
demand is stopped.
A manual override is
still possible: refer to
the installation
manual.
Verify thermostat
batteries.
Verify if maximum
distance between
thermostat and receiver
is not exceeded. Refer to
"Technical
characteristics" in the
installation manual.
Make sure no other
devices are interfering
on the same radio
frequency. Refer to
"Technical
characteristics" in the
installation manual.
Contact your local
dealer.