9. Protection against Legionella
Legionel
On
• On = The
hot water temperature is
increased to 60 °C every 14 days
•
Off
=
no protection
10. Clock
Clock
•
Factory setting 12:00
•
The time can be set under (<<ClockSet>>).
To do this, first set the current hour and
then the current number of minutes
11. Timer Off
Timer
Off
•
The timer function enables timer-cont-
rolled hot-water production with a daily
time frame. To do this, first set the time
under (<<Clock>>).
•
For the starting point, first select the hour
in (<<Start HP .. h>>) and then the minu-
tes in <<Start HP .. min>>.
•
The end time is set in the same way in
(<<Stop HP>>).
•
The legionella programme has priority
irrespective of the timer function.
•
If the power is interrupted, the timer
function is stored by a battery for ap-
prox. 1-2 hours. If the power is interrup-
ted for a period of time longer than this,
the function must be reprogrammed.
12. Configuring separate fan
FanConf
1
Mode display
This function is intended for separate
ventilation with the fan when the heat
pump is in standby mode:
1 = Fan speed 1
(lower quantity of air)
2 =
Fan speed 2
(greater quantity of air)
0 = No separate ventilation function for
the fan.
Fan only to be used when heat pump
in operation!
13. Fan mode (speed selection)
FanMode
2
Fan speed in operation
1 = Speed 1 = low speed/quantity of air
2 =
Speed 2 = higher speed/quantity of air
14. Photovoltaic yield
PV yield
OFF
If the system is connected to a solar power
plant which enables operation of the hot-
water heat pump (HWHP), the following
settings can be selected:
•
«OFF» = the solar power plant is not
connected to the system or is deactivated.
•
«HP» heat pump only, «EL» electric
heating element only, «HP+EL» = the
solar power plant enables the selected
mode when sufficient solar power is
available.
next page
7
4 215 949 / 00
OPerATIOn