4. Operating status data
Status
H. water
Heat pump in hot water mode
Further information:
•
Off
•
DrawDown = HP is in standby mode
according to timer circuit
•
Legionel = heating to 60°C in operation
•
Le.Work
= Legionella programme active
•
Le.End
= Legionella programme
successfully completed
Defrost mode:
•
Defrost gas
•
Defrost air
•
Defrost off
•
Defrost stop
5. Target hot water temperature
Target
HW Target
45 °C
Target hot water
temperature
The set hot water
temperature can be
changed as follows:
1. Press the switch
HW Target
45 °C
F L A S H I N G !
2. Turn the switch
until the desired hot
water temperature is
shown (e.g. 50 °C)
HW Target
50 °C
2. Press the switch =
acknowledge (the new
set temperature is now
in effect). The setting
should be between 45 °C
and 55 °C!
6. Min. hot water temperature
T min
35 °C
Target minimum temperature
This is set in the same way (see point 5,
hot water temperature). If the temperature
falls below this value, the additional heating
selected in the operating mode (point 8) will
be switched on.
7. Min. hot water temperature
T2 min
10 °C
Similar function to «T min».
Is used for the «shutdown function» and
«holiday function». The factory setting is
«10 °C»
8. Heat pump operating mode
H. pump
HP + EL
This is where the heat sources are selected:
•
HP + EL
Heat pump and electric heating element
enabled
•
Off
•
HP = heat pump only
•
EL = electric heating element only
•
Boiler = boiler only
•
HP + Boi. = heat pump and boiler
Only set the installed combination.
next page
6
4 215 949 / 00
OPerATIOn