1. Fuel
Burn only dry, naturally seasoned (min. 2 year old) wood to ensure environmentally friendly combustion
and lower fuel consumption.
2. Lighting
Remove ash from and beneath the combustion chamber.
Stack paper, flammable kindling and wood for approx. 15 cm.
Switch on (main switch ) the boiler.
Close combustion chamber door and loading door.
Light the fire through the lighting door.
Close the lighting door after 5-10 minutes.
Open the loading door carefully and fill up the loading chamber (Insert split logs as parallel as possible).
Close the loading door.
3. Reloading
Open the loading door carefully!
Before reloading, briefly loosen and level the embers.
Add more fuel only if
• the fuel in the loading chamber is mostly burnt and
• the heat of the new load can be absorbed by the heating system and / or the storage tank.
Recommended approach for reloading the boiler:
• If the temperature at the top of the storage tank exceeds 60 °C, but is less than 50 °C in the middle
and at the bottom, fill the chamber completely.
• If the temperature at the top and the middle of the storage tank exceeds 60 °C, but is less than 50
°C at the bottom, fill the chamber partially (depending on the outside temperature).
• Do not add any new fuel if the temperature at the top of the storage tank exceeds 70 °C and has
reached more than 60 °C at the bottom.
For the rest of the day and the night the necessary heat will be provided by the storage tank.
On the following day repeat the steps above, depending on the heat requirements.
4. Flue gas temperature
The flue gas temperature must not exceed 250 °C. If the temperature approaches this limit, the boiler
needs cleaning or you should call a heating engineer.
5. Cleaning and Maintenance
Regularly remove ash from the loading chamber, from the space below the grate and from the com-
bustion chamber. Clean flue gas tracts every 3-4 weeks.
Once a year an inspection and readjustment should be carried out by a heating engineer and the boiler
should be thoroughly cleaned.
6. Shutdown
If the boiler is to be switched off for a long period of time (e.g. in summer), it should be thoroughly
cleaned after the last heating cycle (loading chamber, flue gas tracts, fan unit, combustion chamber,
air ducts).
7. Waste
Burning waste is illegal. Burning contaminated material is environmentally harmful and shortens the
life of the boiler. In particular the lambda sensor will be destroyed.