17
Specification Parameters
Model
H3200
H3400
Power supply
220
~
240V/50Hz
220
~
240V/50Hz
Refrigerant charged
R407C/900g
R407C/900g
Rated cooling capacity (W)
3200
3400
Rated heating capacity (W)
2800
3000
Input power for cooling (W)
1300
1350
Input power for heating (W)
1200
1250
Rated current for cooling
(
A)
5.6
5.8
Rated current for heating
(
A)
5.2
5.4
Maximum input power(W)
1650
1700
Maximum current
(
A)
7.2
7.4
Maximum design pressure
(
kPa
)
2900
2900
Minimum design pressure
(
kPa
)
1840
1840
Maximum air flow
(
l/s
)
150
150
Installed weight
(
kg
)
45+3
45+3
Outdoor unit dimension Height 223mm Width 850mm Length 1122mm
Plenum unit dimension Height 49mm Width 515mm Length 575mm
Notes:
1. All parameters listed are subject to change without notice and the nameplates on the machine
shall prevail;
2. E&OE All values are approximate & subject to change.