13
Operations
LP Vapor Fuel
The model 558 has been factory built to use LP vapor
fuel.
DO NOT use liquid fuel.
NE PAS utiliser de
carburant liquide.
Have a qualified gas serviceman install the LP vapor
fuel supply line to the machine. See below for location of
gas inlet.
Gas Regulator
It is very important that the incoming gas pressure be
between 12.0-14.0 water column inches (.43-.50 PSI).
If your fuel supply does not produce the correct
pressure range contact your local Hotsy Service Repre-
sentative.
The gas pressure coming out of the regulator and going
to the burner ring has been factory set for elevations of
0 to 2000 ft. Altitudes greater than 2000 ft will require
adjustments to the gas manifold pressures. Consult
your local service dealer for high altitude adjustments.
In Canada, certification for installation at altitudes over
4500 feet above sea level is the jurisdiction of local
authorities. You should not readjust the burner ring gas
pressure. If you replace your gas valve, you will need to
adjust the new valve. Refer to your machine’s
specifi-
cation plate
for the correct pressure setting. Follow the
installation and adjustment instructions provided with
your replacement valve.
NOTE: Air for combustion and ventilation along with
exhaust flue sizing must conform to methods outlined
in current American Standard (ANSI-Z223.1) National
Fuel Gas Code or National Standard of Canada CSA-
149.1 and CSA-149.2 “Installation Code for Gas
Burning Appliances”.
Electrical
WARNING: Make sure all switches and controls
are in the OFF position prior to connecting electrical
supply.
AVERTISSEMENT: S'assurer que tous les
commutateurs et tous les contrôles se trouvent en
position d'arrêt avant de raccorder l'alimentation
électrique.
WARNING: DO NOT stand in water while connecting
and disconnecting electrical supply.
AVERTISSEMENT: NE PAS se tenir debout dans l'eau
au moment de brancher ou de débrancher l'alimenta-
tion électrique.
WARNING: Always disconnect power before servicing
your pressure washer.
AVERTISSEMENT: Toujours débrancher l'alimentation
avant d'effectuer des opérations d'entretien sur la
machine.
IMPORTANT: Consult local building codes for exact
electrical requirements. Licensed contractors may
be required.
IMPORTANT: All wiring must be of proper voltage
and amperage rating and conform to applicable
codes.
IMPORTANT: This machine must be electrically
grounded. LA MACHINE DOIT ÊTRE MISE À LA
TERRE.
Grounding Instructions:
Make sure all switches and
controls are in the OFF position prior to connecting
electrical supply. Do not stand in water while
connecting and disconnecting electrical supply. If it
should malfunction or break down, grounding provides
a path of least resistance for electric current to reduce
the risk of electric shock. The product must be
connected to an appropriate power source that is
properly installed and grounded in accordance with all
local codes and ordinances.
DANGER: Improper connection of the equipment
grounding conductor can result in a risk of electro-
cution. Check with a qualified electrician or service
personnel if you are in doubt as to whether the
outlet is properly grounded. DO NOT modify the
plug provided with the product - if it will not fit the
outlet, have a proper outlet installed by a qualified
electrician. DO NOT use any type of adapter with
this product.
DANGER: DANGER: Une mauvaise connexion du
conducteur de terre de l'équipement peut entraîner un
risque d'électrocution. Vérifier auprès d'un électricien
Hotsy 558 DEALER 9.801-536.0 - R
Thermocouple
Connection
Pre
ss
ure Tap
Pilot Ga
s
Outlet
Ga
s
Outlet
to Burner
Ga
s
Inlet
Ga
s
Control
Knob
E.C.O
Terminal
s
Terminal
Panel
Regulator Adju
s
ting
Screw Cover