Safety Information

SAFETY INFORMATION

IMPORTANT SAFETY INSTRUCTIONS

READ AND FOLLOW ALL INSTRUCTIONS

AVOIDING THE RISK TO CHILDREN

DANGER:

RISK OF CHILD DROWNING. 

Extreme caution must be exercised to prevent unauthorized access by children.  To avoid accidents,

ensure that children cannot use a hot tub unless they are supervised at all times.

WARNING:

• To reduce the risk of injury, do not permit children to use this hot tub unless they are closely supervised at all times.
• To reduce the risk of injury, lower water temperatures are recommended for young children. Children are especially sensitive to hot water.

DO:

• Make sure you always lock the child resistant locks after using the hot tub for your children’s safety. Every Limelight

TM

hot tub is equipped

with a locking cover that meets the ASTM F1346-91 Standard for Safety Covers.

• Test the water temperature with your hand before allowing your children to enter the hot tub to be sure that it’s comfortable. Children are

especially sensitive to hot water.

• Remind children that wet surfaces can be very slippery. Make sure that children are careful when entering or exiting the hot tub.

DON’T:

• Allow children to climb onto the hot tub cover.
• Allow children to have unsupervised access to the hot tub.

AVOIDING THE RISK OF ELECTROCUTION

Risk of electrocution

• Connect only to a grounded source.
• Do not bury the power cord. A buried power cord may result in death, or serious personal injury due to electrocution if direct burial-type

cable is not used, or if improper digging occurs.

• A ground terminal (pressure wire connector) is provided on the control box inside the unit to permit connection of a minimum No. 10 AWG

(6 mm

2

) solid copper bonding conductor between this point and any metal equipment, metal water pipe, metal enclosures of electrical

equipment, or conduit within five feet (1.5 m) of the unit as needed to comply with local requirements.

• Do not operate the audio main controls while inside the spa (if spa is equipped with an audio component).
• Do not connect any auxiliary components (for example, cable additional speakers, headphones, additional audio components) to the

audio system unless approved by Watkins Manufacturing Corporation . 

• Do not self service audio component by opening or removing cover as this may expose dangerous voltage or other risk of injury. Refer all

servicing to qualified service personnel.

• Do not attach an external antennae to a spa audio system unless installed by a licensed electrician in accordance with Article 810 of the

National Electric Code, ANSI/NFPA 70.

WARNING:

• To reduce the risk of electrical shock, replace a damaged cord immediately. Failure to do so may result in death or serious personal injury

due to electrocution.

230 volt, permanently installed

• A ground terminal is provided on the terminal block (TB-1, system ground terminal) located inside the control box. To reduce the risk of

electric shock, connect this terminal to the grounding terminal of your electrical service or supply panel with a continuous green, insulated

copper wire. The wire must be equivalent in size to the circuit conductors supplying the equipment. In addition, a bonding terminal

(pressure wire connector) is provided on the outside of the control box for bonding to local ground points. To reduce the risk of electric

shock, this connector should be bonded with a No. 10 AWG (6 mm

2

) solid copper wire to any metal ladders, water pipes, or other metal

within 5 feet (1.5 m) of the hot tub to comply with local requirements. The means of disconnection must be readily accessible, but must be

installed at least 5 feet (1.5 m) from the hot tub.

• Your hot tub is provided with a suitably rated circuit breaker to open all ungrounded supply conductors.

Содержание FLR

Страница 1: ...Page 1 O w n e r s M a n u a l by...

Страница 2: ...____ TELEPHONE ________________________________________________________________________________________________________________ HOT TUB MODEL SERIAL NUMBER ____________________________________________...

Страница 3: ...Inversion 21 HOT TUB CARE AND MAINTENANCE Draining the Water 21 Filter System 22 Filter Cartridge Removal and Cleaning 22 Care of the Hot Tub Pillows 23 Care of the Exterior 23 ELMwood Hot Tub Cabinet...

Страница 4: ...etal water pipe metal enclosures of electrical equipment or conduit within five feet 1 5 m of the unit as needed to comply with local requirements Do not operate the audio main controls while inside t...

Страница 5: ...es within 5 feet 1 5m of the hot tub Use an extension cord to connect the hot tub to its power source The cord may not be properly grounded and the connection is a shock hazard An extension cord may c...

Страница 6: ...nce the tolerance of temperature regulating devices may vary by as much as 5 F Test the water with your hand before entering the hot tub to be sure it s comfortable SAFETY SIGN Each Limelight TM hot t...

Страница 7: ...7 0 x 7 0 2 13m x 2 13m 230v System 230 volt 50 Amp single phase GFCI protected circuit 36 91m 65 square feet 4 000 310 gallons 1170 litres 789 lbs 358 kg 4 267 lbs 1 935 kg 110 lbs per square foot L...

Страница 8: ...e Even with stones in place the hot tub will inevitably settle and become unlevel Plus a hot tub surrounded by dirt or grass will soon be filled with dirt or grass from users feet therefore it s impor...

Страница 9: ...acing the hot tub on an elevated deck or platform IMPORTANT Watkins Manufacturing Corporation reserves the right to change any specifications or design without incurring any obligation Hot Tub Levelin...

Страница 10: ...ional accessory 7 Bonding terminal OVERHEAD VIEWS A Combination XL Hydromassage jets B Combination Hydromassage jets C Direct Hydromassage jets D Secondary suction E Hot tub pillow F Filter compartmen...

Страница 11: ...sory 7 Bonding terminal 2 4 7 6 5 OVERHEAD VIEWS A Combination XL Hydromassage jets B Combination Hydromassage jets C Direct Hydromassage jets D Secondary suction E Hot tub pillow F Filter compartment...

Страница 12: ...artment G Control panel H Air Lever for Direct Hydromassage jets I Cup holder J Water Feature lever K Water Feature L Heater jet Ozone optional accessory B A A E F G K I H D C C E B D H L C C C J J B...

Страница 13: ...Loosen the screws on the front of the control box Remove the screws and the control box cover 3 Route the electrical service from the subpanel into the hot tub equipment compartment NOTE The subpanel...

Страница 14: ...seconds then push the breaker switch to the OFF down position to ensure that it has completely disengaged then push the breaker switch to the ON up position If you don t wait 30 seconds the hot tub s...

Страница 15: ...10 000 pre filter if treating your hot tub with a polyhexamethylene biguanide Biguanide PHMB i e BaquaSpaTM sanitizer 1 Close drain and fill the hot tub with water through the filter compartment The...

Страница 16: ...water temperature by pressing the TEMP button on the control panel or lower it by pressing TEMP button After a few hours the water temperature will remain within 1 1 2 degrees of your selected tempera...

Страница 17: ...spin freely a second night of soaking is required If the bearing still does not spin you will need to purchase a replacement assembly from your LimelightTM dealer 4 To replace position the cutout at t...

Страница 18: ...st be in ON position Jet Pump 2 Jet System 1 Diverter lever in the 6 o clock position 6 Direct jets on back wall 8 Direct jets on right back wall 1 Combination XL jets on right front wall 4 Direct jet...

Страница 19: ...ack wall 4 Direct jets in lounge footwell 1 Combination XL jet in footwell 1 Combination XL jet on front left wall 1 Water Feature right wall lever must be in ON position LIMELIGHT TM FLAIR TM MODEL F...

Страница 20: ...t left wall 2 Direct jets on front left wall 2 Combination jets on front left wall 2 Combination jets in footwell Jet Pump 1 10 Direct jets on left back wall 6 Direct jets jets on right back wall 2 Co...

Страница 21: ...ub The control panel display responds to let you know you ve pressed a button and that the selected function has been performed After a period of non use pressing any button will wake up a sleeping di...

Страница 22: ...her the hot tub water is above its acceptable temperature range or a malfunction has occurred within the hot tub such as low circulation due to a clogged filter An off POWER indicator means that there...

Страница 23: ...submenus where the CLEAN symbol is illuminated on the display Press the OFF button to deactivate NOTE Pressing the JETS button will also deactivate the clean cycle LOCKING FEATURES The two locking fea...

Страница 24: ...tub the Summer Mode timer will reset starting with the 8 hour shutdown mode If a different 8 hour shut down time is desired deactivate the Summer Mode then reactivate at the beginning of the desired e...

Страница 25: ...that more frequent filter cleanings are required Failure to maintain the cartridge in a clean unobstructed manner will result in reduced water flow through the heater assembly that may cause the High...

Страница 26: ...FreshWater Stain and Scale Defense to use if your hot tub water has a high concentration of dissolved minerals 2 The use of alcohol or any household cleaners other than those listed to clean the hot...

Страница 27: ...prings and pivot points of the retractable cover system Ice buildup may damage system components WARNING The vinyl cover and retractable cover system are not recommended for use in wind conditions rea...

Страница 28: ...water by following the shock procedures Return the set temperature to its original setting The hot tub water will be safe for you to use once the Free Chlorine Residual level has dropped below 5 0 ppm...

Страница 29: ...ave clean water Water maintenance is one of the most important areas of hot tub ownership Your dealer can guide you through the process of achieving and maintaining perfect water in your hot tub given...

Страница 30: ...hands in your eyes on the hot tub shell surface or on the cabinet 4 After ten minutes turn the jet pump off and close and secure the cover to complete the procedure Risk of Drowning Never leave an op...

Страница 31: ...alkaline those below 7 are acidic Maintaining the proper pH level is extremely important for Optimizing the effectiveness of the sanitizer Maintaining water that is comfortable for the user Preventin...

Страница 32: ...he hot tub is being used over an extended period of time such as a whole afternoon or evening additional sanitizer will be needed A weekly shock treatment is required The shock treatment quickly destr...

Страница 33: ...s Limelight Glow Model GLW 1 5 teaspoons As needed if water is hazy cloudy or has an odor OR OR MPS is an oxidizer not a sanitizer Page 30 Page 30 FRESHWATER Ag SILVER ION PURIFIER REPLACEMENT When re...

Страница 34: ...come cloudy CHLORINE SODIUM DICHLOR A Sanitizing chemicals such as chlorine are oxidants that kill bacteria and viruses in the water The Free Available Chlorine FAC is a measure of the amount of unuse...

Страница 35: ...high concentrations of minerals The use of a low water volume extra fine pore water filter in line pre filter such as the FreshStart 10 000 pre filter will help to remove many of the larger particles...

Страница 36: ...t with the jet pump operating for ten minutes DO use special care if using baking soda to clean either the interior or exterior plastic surface DON T use swimming pool muriatic acid to lower pH DON T...

Страница 37: ...many chemicals and in such large amounts Answer While over exposure to any chemical can be unhealthful many low levels of chemicals are effective and beneficial In the case of hot tub water the chemic...

Страница 38: ...setting a high limit thermostat or replacing a light bulb may not require a service call they may indicate that a more serious condition exists These conditions may require an experienced service pers...

Страница 39: ...than others and will shut the pump off at lower temperatures High temperature All Limelight hot tubs models are equipped with a jet pump shroud that vents the heat generated by the pump motor to the...

Страница 40: ...circumstances shall Watkins Manufacturing Corporation or any of its representatives be held liable for injury to any person or damage to any property however arising WATKINS CUSTOMER SERVICE If you ha...

Страница 41: ...em Probable causes Solutions TROUBLESHOOTING Should you experience any problem do not hesitate to contact your authorized Limelight dealer Here are some tips to help you to diagnose and rectify some m...