background image

Fixed glass sheet

Door

Usual Detection Row

1R
2R
6R

Top View

Detecting doorway when the door closed.
(the sensor is OFF.)
Normal position is this.

Dip Switch

5   1

st

 Row Detection

Doorway detection function can be selected as follows.

When the 1

st

 Row is used for the detection of doorway, please set Dip Switch as follows.

Even after setting 1

st

 Row to <Doorway>, if the door still closes, set the detection area as

follows not to detect the door.

If only the detection of Doorway Row occurs, and has judged malfunction of the door, re-start the initialization process.
Initialization Indicating LED starts flashing when initialization.

Initialization of a sensor (door learning process) is necessary for doorway detection. This process is made every time of
Power-ON, it is completed after the sensor has learned the movement of persons 2 or 3 times. The state of Initialization
process is confirmed with Initialization Indicating LED.

Initialization

Initialization Indicating LED

-3-

-6-

Initialization process is not necessary in this case. Initialization Indicating LED does not flash even after Power-ON.

5.1   1

st

 Row Detection (Doorway Detection Mode)

Doorway

Dip Switch

4   Doorway Detection when closed

ON

OFF

door

6
R

5
R

4
R

3
R

2
R

1
R

door

6
R

5
R

4
R

3
R

2
R

1
R

Not detecting doorway when the door
closed. (the sensor is OFF.)
Combined with other security systems
<OFF> is useful.

Under Initialization : Initialization Indicating LED flashes. Not detecting doorway.
After Initialization : Initialization Indicating LED does not flash. Detecting doorway.

The 2

nd

 6

th

 Row except Doorway Row are not necessary for the Initialization process above, and they

operate in the same manner of usual reflection sensors.

CAUTION

5.2   1

st

 Row Detection (Usual Mode)

When the 1

st

 Row is used as the usual detection, and activation area (detection depth area) is to be enlarged,

please set detection area as follows.

Dip Switch

5   1

st

 Row Detection

Normal

Detection Area can be adjusted using Area Mask.

Area Mask Tuning Knob

L

R

N : NARROW   W : WIDE

Please turn Area Mask to stop in 

click

To be deleted
by <L> Area Mask

Door Side

In the position of NARROW, Area Mask
is seen in white over the lenses.

3. Area Mask

Front
View

To be deleted
by <R> Area Mask

To be deleted
by <L> Area Mask

To be deleted
by <R> Area Mask

Just under
the sensor

Top

View

1    After installation of the sensor, please check sensitivity Dip Switch set to <M>
      (Dip Switch

1   2. Default is <M>.)

2    Please adjust the Mounting Height.
      (Dip Switch

3.  Default is <2.5 

 4m>.)

3    Sensitivity is adjusted automatically. Before applying power, please check no objects (stepladder, tools etc.) are left in the detection area.

After applying power, do not enter into the detection area within 10 seconds.
(If there is a person inside the detection area within the detection seconds, setting sensitivity cannot be made properly.)

Do not enter into the detection area within 10 seconds

10 seconds

Power

ON

Presence

Detection

1.

   If mounting and various settings are completed, the power and confirm

      the performance of detection area.

2.

   If the door does not operate normally, turn off the power and re-set

      the detection area.

3.

   If the door does not function normally after the above procedure,

adjust Dip Switch.

4.

   When adjusting the detection area or sensitivity by Dip Switch,

      turn off the power first.

When re-setting, turn on the power according to <7. Sensitivity Settings

      (Precaution on Power-ON)>.

How to set sensitivity :

Self-Monitoring means the sensor is equipped with microprocessor control function and continuously monitors itself.
When Self-Monitoring determines that the sensor has malfunctioned, Operation Indicator LED and Power Indicator LED will blink alternately with the
door remained open. In this case, please replace the sensor immediately.
ON / OFF of Self-Monitoring can be set with Dip Switch.

7. Sensitivity Settings (Pre-caution on Power-ON)

Before applying power, please check the wiring again and follow instructions below.

CAUTION

When the actual Mounting Height is 2.5 

3m, either setting <2 

 3m> or <2.5 

 4m> can be selected. In this case, Default

<2.5 

 4m> is recommended.

CAUTION

CAUTION

If there is a moving object in the detection area after Power-ON, the sensor will not be in Presence Detection mode.
After removing of the person or object, the sensor will be in Presence Detection mode in 7 seconds.

CAUTION

When set to 

, please be noted there would be a case the door remains open if the surface of the detection floor changed suddenly.

In that case, please turn off the power and try again.

CAUTION

While carrying out followings, please turn off the power. If you carry out followings when the power is ON, the door will remain open
for the period of Presence detection time you set. And also the Initialization will start again.

In case of alteration of Detection Area, or re-adjustment of Sensitivity.
In case of laying or removing a cloth/resin mat in the Detection Area.

9. Self-Monitoring

(1)   When the sensor does not detect a person in the detection area,

adjust <Dip Switch    1 2> (H) side.
(Sensitivity increases)

(2)   When the sensor detects a person even if no one exists in

the detection area, adjust <Dip Switch    1 2>  (L) side.
(Sensitivity decreases)

If the floor of Detection Area is specular surface, Self-Monitoring may function. In that case, set Self-Monitoring <OFF>
with Dip Switch.

CAUTION

8. Verification of Operation

Y

Y

Y

Y

Y

Y

Y

N

N

Side View

door

6
R

5
R

4
R

3
R

2
R

1
R

Side View

door

6
R

5
R

4
R

3
R

2
R

1
R

The 1

st

 Row detection area should

not be overlapped with the door.

Door

Doorway Detection Row

1R
2R
6R

Top View

Fixed glass sheet

Отзывы: