Indesit
Company
23
of 29
Service Manual UK
English
SMARTCARD PROGRAMMING PROCEDURE - FLOWCHART
DISCONNECT
(unplug)
THE
APPLIANCE
FROM
THE
ELECTRICAL
SUPPLY
(grid)
INSERT
A
VALID
SMARTCARD,
RELATING
TO
THE
MODEL
&
MAIN
POWER
MODULE
(board)
TO
BE
PROGRAMMED,
INTO
THE
SMARTCARD
READER
INSERT
THE
SMARTCARD
READER
INTO
EITHER
THE
SERIAL
PORT
OF
THE
POWER
MODULE
(BOARD)
OR
INTO
THE
LOW
END
ADAPTOR
(Version
2007)
WHERE APPLICABLE
RE
Ͳ
CONNECT
THE
APPLIANCE
TO
THE
ELECTRICAL
SUPPLY
(GRID).
A
STATIC
RED
LED
WILL
LIGHT
UP
TO
SIGNAL
THAT
THE
SMARTCARD
READER
IS
SUPPLIED
CONNECTION
IS
VERIFIED
(OK)
DOWNLOAD
NOW
IN
PROGRESS
THE
POWER
MODULE
IS
NOW
PROGRAMMED.
DISCONNECT
(unplug)
THE
APPLIANCE
FROM
THE
ELECTRICAL
SUPPLY
(grid)
REMOVE
THE
SMARTCARD
READER
(DISCONNECT
THE
LOW
END
ADAPTOR
WHERE
USED)
IF
THE
RED
LED
IS
FLASHING
x
COMMUNICATION
PROBLEM
x
SMARTCARD
INVALID/ERASED
DISCONNECT
(unplug)
THE
APPLIANCE
FROM
THE
ELECTRICAL
SUPPLY
(grid)
DOWNLOAD
OK
THE
SMARTCARD
CONTENT
WILL
BE
AUTOMATICALLY
ERASED
IF
THE
RED
LED
IS
STATIC
(fixed):
x
DOWNLOAD
HAS
FAILED
(KO)
IF
THE
DOWNLOAD
FAILED
THE
SMARTCARD
WOULD
NOT
HAVE
BEEN
ERASED
DISCONNECT
THE
SMARTCARD
READER
FROM
THE
APPLIANCE
AND
THE
SMARTCARD
FROM
THE
SMARTCARD
READER
RESOLVE
THE
PROBLEM:
FURTHER
DIAGNOSTICS
MAY
BE
REQUIRED
ON
THE
APPLIANCE
NO
YES
NO
YES
IS
THE
GREEN
LED
FLASHING?
IS
THE
GREEN
LED
STATIC?
START
DISCONNECT
THE
SMARTCARD
READER
FROM
THE
APPLIANCE
AND
THE
SMARTCARD
FROM
THE
SMARTCARD
READER
AND
ACTION
BELOW:
If
the
RED
LED
was
flashing
SLOWLY
,
and
a
smartcard
was
inserted,
check
for
the
following:
x
Invalid/erased
smartcard
(previously
used)
Discard
the
invalid
smartcard,
x
Incorrectly
inserted
smartcard,
(check
orientation
of
the
smartcard
chip)
x
Poor
connection
between
the
smartcard
and
smartcard
reader.
If
the
RED
LED
was
flashing
RAPIDLY
,
check
for
the
following:
x
Ensure
a
smartcard
was
inserted
into
the
smartcard
reader,
x
Ensure
the
smartcard
was
fully
inserted?