FAULT DISPLAY
The FAULT is indicated by an '
F
' on the left hand side digit and the fault number in the '
XX
' format on
the right.
AUTOTEST ACTIVATION
The autotest function starts with the appliance off.
If there is a Last Fault in the memory, the appliance shows it immediately for 20 seconds, after which
the Autotest sequence commences.
The Last Fault only cancels at the end of the Autotest sequence. If the autotest is interrupted, the Last
Fault is presented again when the procedure is restarted.
On completion of the autotest, a long beep sounds and the appliance turns OFF again. The Last Fault
transfers to rolling visible memory only via the Cooling Doctor diagnostic tool.
AUTOTEST SEQUENCE
AUTOTEST ACTIVATION
DISPLAY
ACTIVATION
Long press of the Super Freeze key for 6
seconds (or Super Cool on single door fridges).
-
All LEDs light up for 2 seconds.
-
The Last Fault is shown (where present) for
20 seconds.
-
All LEDs light up for remaining duration of
the autotest.
Step
Duration
Action
FG Light
Note
1
5 seconds
Pause
OFF
2
1 second
Probe check
OFF
If the probe control is OK, it skips to step 3.
If there are probe faults (KO), it skips to
step 5.
3
4 seconds
Pause
OFF
4
245 seconds
FG fan ON
ON
After this test, it skips to step 6
5
245 seconds
FG fan ON
Blinking
6
End of Autotest