Upper exhaust flue
• Slightly widen the two sides of the upper flue
and hook them behind the brackets
7.2.1
, making
sure that they are well seated.
• Secure the sides to the brackets using the 4
screws
12e
(2,9 x 9,5) supplied.
Lower exhaust flue
• Slightly widen the two sides of the flue and
hook
them between the upper flue and the wall,
making sure that they are well seated.
• Fix the lower part laterally to the hood body
using the 2 screws
12e
(2,9 x 9,5) supplied.
Connections
DUCTED VERSION AIR EXHAUST SYSTEM
When installing the ducted version, connect the hood to the chimney using either a flexible or rigid
pipe ø 150 or 120 mm, the choice of which is left to the installer.
• To install a ø 120 mm air exhaust connection,
insert the reducer flange
9
on the hood body
outlet.
• Fix the pipe in position using sufficient pipe
clamps (not supplied).
• Remove any activated charcoal filters.
RECIRCULATION VERSION AIR OUTLET
• Push the connection
15
onto the air outlet
.
• Insert the connection extension pieces laterally
14.1
in connection
15.
• Fix the connection extension
14.1
to the
connection
15
using the 4 screws
12b
(3,5)
supplied.
• Ensure that the activated charcoal filters have
been inserted.
9
ø 120
ø 150
14.1
15
12b
Flue assembly