Страница 1: ...on 5407324 Issue 2 Jan 2007 HOTPOINT FREESTANDING FROST FREE FRIDGE FREEZER Model Comm Covered Code FF175BP 39772 lndesit Company UK Ltd 2007 Reg Office Peterborough PE2 9JB Registered in London 106725 VVPL00003242_0001 ...

Страница 2: ...s and or electrical equipment including cordless power tools are forbidden within the storage area working area and vehicles used to transport lsobutane 9 The carrying case for the scales and refrigerant must display a red flammability label Part Number 8100063 which should be visible and readable at all times 10 The vehicle and storage area must be ventilated as far as is reasonably practicable a...

Страница 3: ...as Part Number 2602600 2 Canisters must be stored inside the aluminium case with the weighing scales for protection from possible damage and heat The aluminium case must NEVER be placed next to a heat source or in direct sunlight 3 lsobutane must only be dispensed to the appliance from the 420 gramme aluminium canister placed in an upright position on the weighing scales provided 4 A blue returns ...

Страница 4: ...gram 24 Thermistor Sensor Location 25 INDUSTRIAL CODE I SERIAL NUMBER FORMAT SIN Serial Number 406250042 created from 4 Year of Manufacture 06 Month 25 Day of month 0042 Number of appliances produced on this day The Serial Number along with the Industrial Code and Commercial Code are on the bottom line of the Rating Plate as detailed in the example below Industrial Code Revision changes Commercial...

Страница 5: ...ensor is double insulated and in the unlikely event of failure a section of the control module is programmed to respond and control the functions on a timed basis from there on in Defrosting is automatic Full Frost Free All models have rear wheels located in the compressor base plate with adjustable feet fitted to the front The climate class is SN I ST signifying that it is designed to operate in ...

Страница 6: ...ss Electrical Supply Voltage Frequency Energy Consumption kWh year kWh 24 Hours Energy Band Defrosting Anti Condensation Heater Introduction Date May 2006 FF175BP Unpacked 1750 mm 600mm 655mm 64 kg Fridge 175 litres 173 litres Freestanding Packed 1810 mm 670mm 720mm 67 85 kg Poland Yes 8 4 Star 12 Minimum Aperture 1850 mm 700mm Freezer 85 litres 65 litres SN IN I ST 10 C to 38 C 220 240 v 50 Hz 32...

Страница 7: ...let Duct Heater Q Foamed In Defrost Thermostat Protector Cut In 5 C 5 C Thermal Fuse Refrigerant Charge R600a Compressor Winding Resistance Q Start Run Capacitor 387 2 1 61k 16 13k 72 C Refer to Rating Plate Tecumseh TWB1370MJS 26 75 15 75 Refer to Parts List 7 Cut Out 10 C 3 C VVPL00003242_0007 ...

Страница 8: ...Ice Tray FREEZER and STORAGE Compartment ICE CARE Ice Tray STORAGE Compartment LEVELLING Feet DETAILED VIEW I I 1 s rr c _ f J 4 d1 I ICJ I T I I J I 1 v r J T I I J J Varies by number and or position 8 9 __ l v Removable Lidded Shelf with EGG TRAY Removable Multipurpose SHELVES BODLE Shelf VVPL00003242_0008 ...

Страница 9: ... Fan Module The freezer fan is located in front of the evaporator coil and is designed to distribute the cold air produced by the evaporator coil uniformly inside the freezer compartment and when necessary in the fridge compartment The freezer fan is managed by the module and is switched on off after a preset time interval that is parameterised in the module after a compressor start stop The defro...

Страница 10: ...it The same minimum safety time is observed in the event of a mains power interruption voluntary or involuntary This compressor protection strategy is observed only after the product has been operating continuously for the number of hours defined in the module memory 2 Long periods of activity if the compressor remains on for more than the time parameter set in module memory it is switched off eve...

Страница 11: ...escribed a setting control knob from fault is the OFF position detected 3 Turn the control knob from or Temperature Sensor maximum to the thermistor minimum setting Switching OFF appliance OFF the power supply position Auto Test Sequence 1 Heaters 6 second test For the Auto test to check the heater circuit the evaporator must be sensing a temperature of 10 C or colder The defrost gutter and duct h...

Страница 12: ... THE INLET DUCTING NOTE THE DAMPER BAFFLE IN THE FRIDGE MULTI FLOW UNIT NEEDS TO BE IN THE OPEN POSITION FOR THIS TO HAPPEN THE FAN DRAWS AIR THROUGH THE EVAPORATOR AND BLOWS IT INTO THE TOP OF THE DUCT PANEL IT IS THEN CHANNELED TO THE INDIVIDUAL FREEZER BASKETS VIA 8 OUTLET PORTS THE EVAPORATOR FAN DRAWS AIR FLOW FROM THE FRIDGE EXHAUST BACK THROUGH THE EVAPORATOR NOTE THE DAMPER BAFFLE IN THE F...

Страница 13: ...THROUGH THE EVAPORATOR ASSEMBLY IT IS THEN BLOWN BETWEEN THE FRONT AND REAR DUCT PANELS AIR FLOW IS THEN CHANNELLED AND DISTRIBUTED UNI FORMALLY TO THE OUTLET PORTS OF THE FRONT AIR DUCT AIR FLOW IS DIRECTED TO THE INDIVIDUAL STORAGE DRAWERS THE ABOVE PROCESS IS REPEATED SO LONG AS THE EVAPORATOR FAN IS RUNNING 13 VVPL00003242_0013 ...

Страница 14: ...tion the compressor switches on once a minimum safety time lag has elapsed since the last power off thereby allowing refrigerant gas pressure to reach a point of equilibrium in the refrigerant circuit 8 minutes The same minimum safety time is observed in the Compressor Operation event of a mains power interruption voluntary or involuntary This compressor protection strategy is observed only after ...

Страница 15: ...st defrost cycle 720 minutes 2 Duration of doors open condition If the door is opened more than 60 minutes there is a defrost every 2 hours 1 The defrost procedure is preceded by activation of the fan for a timed interval that is parameterised in the module memory 4 minutes 2 After the defrost cycle the fan starts after a timed interval following a compressor start also this interval is parameteri...

Страница 16: ...ressor Start or Run windings Check the resistances of the faulty compressor windings There are situations of cooling See CONTROL MODULE Parameters demand in which the compressor page 14 Section headed Compressor remains OFF Operation Mains plug fuse blown Check fuse rating If the fuse is of the COMPRESSOR correct rating and has blown then check NOT RUNNING appliance for reasons Fridge Interior App...

Страница 17: ...ing module and is switched ON OFF Check fan assembly after a pre set time interval that is Check fan blades are free to rotate parameterised in the module Check wiring and connections memory after a compressor start FREEZER stop EVAPORATOR Defrost cycle enabled Advise the customer that the fan will not FAN NOT run during the defrost cycle RUNNING Fridge door open Close fridge door Check magnet pos...

Страница 18: ... control module from the panel NOTE On reassembly align the control knob to the potentiometer mounted on the module When assembled check that the temperature selector can rotate through all its settings E Door Seals replaceable NOTE There is a moulding at the rear of the door seal that locates into a groove in the door liner to secure it 1 To replace ease the seal away from the door liner starting...

Страница 19: ... duct cover See photo 1 3 Insert a slotted screwdriver into the cover upper vent holes to unclip the cover from the duct assembly See photo 1 4 Pull cover forward and withdraw See photo 2 5 With the cover removed unclip the duct assembly from the sides of the freezer liner and withdraw assembly complete with fan motor housing See photo 3 6 Disconnect fan wiring from the terminal block 7 Pull fan i...

Страница 20: ...inal fixing screws are reused to refit it Fig 1c Remove the hinge blanking covers from the control panel and remove the top hinge invert and transfer them over to the other side The original fixing screws are reused to refit it Fig 2 B Front Base Moulding Plinth Unscrew the two front screws securing the plinth to the base and remove plinth Remove the lower hinge and slide down the fixing plate tra...

Страница 21: ...er door onto the bottom hinge pin While supporting the door screw the centre hinge into position Fig Sc Place the fridge door onto the centre hinge pin and align it with the top hinge assembly and screw the top hinge pin in Refit the hinge blanking plug and the door hinge surround strip to the fridge door noting that the cut out end corresponds with the hinge Fig Sd NOTE On the reverse side of the...

Страница 22: ...BROWN To Terminal Block E L WHITE To Terminal Block H M YELLOW To Terminal Block D DEFROST HEATER AND THERMAL FUSE CONNECTION PLUG REAR VIEW WIRE SIDE DEFROST THERMOSTAT AND THERMAL FUSE DEFROST HEATER AND THERMAL FUSE CONNECTION SOCKET Q J fEvaporator Defrost D Heater Gutter Heater Freezer Duct ro g Heater if fitted c c QJ QJ c o Defrost Thermostat 1 1 Control PCB Terminal Block W2 Terminal numbe...

Страница 23: ... LINE LIVE NEUTRAL W2 TERMINAL CONNECTIONS COMPONENT THERMAL FUSE THERMAL PROTECTOR DEFROST THERMOSTAT FREEZER EVAPORATOR FAN MOTOR FREEZER EVAPORATOR FAN MOTOR W3 IDC CONNECTIONS J COMPONENT COLOUR 1 FRIDGE INTERIOR LAMP NOT USED e re FRIDGE INTERIOR LAMP NOT USED NOT USED NOT USED NOT USED NOT USED W4 IDC CONNECTIONS COMPONENT FREEZER AIR SENSOR THERMISTOR FREEZER AIR SENSOR THERMISTOR 23 W4 VVP...

Страница 24: ...l Fuse L Cut In 5 C 5 C 72 C Denotes Connector Block I Socket Terminations See page 22 Wiring Connection Chart FREEZER AIR SENSOR THERMISTOR FRIDGE INTERIOR LAMP I CAPACITOR T if fitted Cut Out 10 C 3 C N D C Denotes Connector Socket Terminations internally linked See page 22 Wiring Connection Chart G F Denotes Connector Socket Terminations internally linked See page 22 Wiring Connection Chart NOT...

Страница 25: ... Freezer Cabinet Located on the compressor step behind the duct mounting on the right SENSOR RESISTANCE TABLE Q Temperature C Resistance kn 30 175 25 129 2 20 96 3 15 72 5 10 55 5 42 1 0 32 5 5 25 3 10 19 8 15 15 6 20 12 4 25 10 30 8 35 6 5 40 5 3 45 4 3 50 3 6 55 2 9 60 2 4 65 2 70 1 7 25 VVPL00003242_0025 ...