background image

 

4

 

 

HHB468SE 12-09-13 

 

Ventilation

No purpose provided ventilation is normally required for stoves rated under 5KW. However for 

newer build properties or properties that have been modified so that the design air permeability is less than 
5m

3

/h.m

2

a permanent ventilator will need to be fitted. Approved document J of the building Regulations 

gives more detailed information. For each KW above 5KW, 550 sq mm of fixed ventilation is required – i.e. 
a stove rated at 8KW would require 3 x 550 sq mm = 1650 sq mm of fixed ventilation. If more than one 
appliance is installed in the same room, the ventilation requirements for each appliance must be added 
together. 

 

There must not be an extractor fan fitted in the same room as the stove as this can cause the stove to emit 
fumes into the room. 
 

Health and Safety Precautions 
Works must be carried out with care to meet the requirements of Health and Safety (Health and 
Safety at Work Act 1974) and comply with the Health and Safety rules contained therein, and any 
new regulations introduced during the lifetime of these instructions. 
Handling 

Adequate facilities must be available for unloading and site handling. Hothouse Cassette Stoves are very 
heavily built so always ask for assistance when lifting and siting the stoves. 

Fire Cement 

Some types of fire cement are caustic and should not be allowed to come into contact with the skin. In case 
of skin contact, wash immediately with plenty of water. 

Asbestos 

This stove contains no asbestos. If there is a possibility of disturbing any asbestos in the course of 
installation then please seek specialist guidance and use appropriate protective equipment. 

Metal Parts 

When installing or servicing this stove, proper care should be taken to avoid the possibility of personal 
injury. 

 

4.0

 

Installation Information 

 
Chimney 

The chimney height and the position of the chimney terminal should conform to Building Regulations. 
Minimum chimney height is 4.5m. Check that the chimney is in good condition, dry, free from cracks and 
obstructions. The diameter of the flue should not be less than 150mm and not more than 200mm. If any of 
these requirements are not met, the chimney should be lined by a suitable method. The chimney must be 
swept before connection to the stove. 
Where the chimney is believed to have previously served an open fire installation, it is possible that the 
higher flue gas temperature from the stove may loosen deposits that were previously firmly adhered, with 
the consequent risk of flue blockage. It is therefore recommended that the chimney be swept a second time 
within a month of regular use after installation. 
If you have any doubts about the suitability of your chimney, consult your local dealer/stockist or chimney 
specialist. If there is no existing chimney then either a solid fuel compatible prefabricated block chimney or 
a twin-walled insulated stainless steel flue to BS 1856-1 can be used. These chimneys must be fitted in 
accordance with the manufacturer‟s instructions and also please refer to the current issues of British 
Standards BS EN 15287-1:2007 for design, installation and commissioning of chimneys. 
 

Ventilation 

No purpose provided ventilation is required for stoves rated under 5KW. For each KW above 5KW, 550 sq 
mm of fixed ventilation is required – i.e. a stove rated at 8KW would require 3 x 550 sq mm = 1650 sq mm 
of fixed ventilation. If more than one appliance is installed in the same room, the ventilation requirements 
for each appliance must be added together.  
 

 
 

Содержание HHB4SE

Страница 1: ...ASE READ ALL THESE INSTRUCTIONS CAREFULLY For safety reasons it is essential that your stove is correctly installed and operated Hothouse cannot accept responsibility for any fault or consequential pr...

Страница 2: ...Connection to Chimney 4 Material Clearances 5 Hearths 5 Commissioning Handover 5 5 Technical Data 6 6 Operating Instructions 6 Air controls 6 Cleaning 7 Fuels 7 Notes on Wood Burning 7 Lighting the st...

Страница 3: ...tove assembly and controls Fig 2 HHB4SE Stove Assembly and controls Description of Parts Qty Hothouse Stove Assembly 1 Tool 1 Ash Pan 1 Flue Collar 1 Flue Collarfixing screws Washers 4 Legs 4 Stove Op...

Страница 4: ...rning This stove must notbe installed into a chimney that serves any other heating appliance Extractor Fan Warning There must not be an extractor fan fitted in the same room as the stove as this can c...

Страница 5: ...tal Parts When installing or servicing this stove proper care should be taken to avoid the possibility of personal injury 4 0 Installation Information Chimney The chimney height and the position of th...

Страница 6: ...that all connections between the stove and chimney flue are sealed and made airtight with sealing rope clamping rings and or fire cement or heat resisting cement where required Both the chimney and f...

Страница 7: ...provide much more or less than their rated heat outputs depending upon how they are burnt and fuels and fuel loads used On completion of the installation and commissioning ensure that the operating in...

Страница 8: ...mportant to use the rotary grate to de ash regularly to ensure that the primary airflow is not impeded as a build up of ash can damage the cast iron bed Ashpan It is essential that you empty the steel...

Страница 9: ...en Leave the door slightly ajar for 10 minutes to enhance initial starting and reduce smoke emission DO NOT leave the stove unattended if the door is left ajar Allow the fuel to reach a steady glow an...

Страница 10: ...ROUS Always use a fireguard in the presence of children the elderly or the infirm DO NOT perform modifications to the appliance as this could seriously compromise safety in operation DO NOT OVERFIRE i...

Страница 11: ...all air controls fully Move furniture and rugs away from the fireplace and remove any nearby ornaments Place a fireguard or spark guard in front of the stove Feel the chimneybreast for sign of excess...

Страница 12: ...attends any stove problem that is not related to product failure 6 Where can I get spare parts Your local Hothouse Stove retailer will be pleased to supply spare parts and to provide any other inform...

Страница 13: ...ireboard Y1HDF04D06E 28 Front Y1HDF04D34E 07 Side Plate Right fireboard Y1HDF04D07E 29 Base Y1HDF04D35E 08 Riddle Grate Y1HDD08E 30 Side Right Y1HDF04D36E 09 Grate for Riddle Grate Y1HDF04D12E 31 Side...

Страница 14: ...de Plate Right fireboard Y1HDF06D07E 28 Front Y1HDF06D34E 08 Riddle Grate Y1HDD09E 29 Base Y1HDF06D35E 09 Grate for Riddle Grate Y1HDF06D12E 30 Side Right Y1HDF06D36E 10 Grate Mounting Bracket Left Y1...

Страница 15: ...de Plate Right fireboard Y1HDF08D07E 28 Front Y1HDF08D34E 08 Riddle Grate Y1HDD09E 29 Base Y1HDF08D35E 09 Grate for Riddle Grate Y1HDF08D12E 30 Side Right Y1HDF08D36E 10 Grate Mounting Bracket Left Y1...

Страница 16: ...in a smoke control area unless it is used in an exempt appliance exempted from the controls which generally apply in the smoke control area The Secretary of State for Environment Food and Rural Affair...

Отзывы: