background image

 

15

 

 

HHB468SE 12-09-13 

 

 

 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

HETAS Ltd Approval

 

    

These appliances have been approved by HETAS Ltd as intermittent operating appliances for burning wood 
logs only. 

 

   

Please note that HETAS Ltd Appliance Approval only covers the use of wood logs on this appliance. HETAS 
Ltd Approval does not cover the use of other fuels either alone or mixed with the recommended fuels listed 
above, nor does it cover instructions for the use of other fuels.

 

 

Hothouse Inspired Products Ltd 

Imperial Point 

Express Trading Estate 

Stonehill road 

Farnworth 

Bolton BL4 9TN 

 

Tel:01204 - 862286Fax:01204 - 868569

 

 

“The Clean Air Act 1993 and Smoke Control Areas”

 

 
Under the Clean Air Act local authorities may declare the whole or part of the district of the

 

authority to be a smoke control area. It is an offence to emit smoke from a chimney of a

 

building, from a furnace or from any fixed boiler if located in a designated smoke control area.

 

It is also an offence to acquire an "unauthorised fuel" for use within a smoke control area

 

unless it is used in an "exempt" appliance ("exempted" from the controls which generally

 

apply in the smoke control area).

 

The Secretary of State for Environment, Food and Rural Affairs has powers under the Act to

 

authorise smokeless fuels or exempt appliances for use in smoke control areas in England. In

 

Scotland and Wales this power rests with Ministers in the devolved administrations for those

 

countries. Separate legislation, the Clean Air (Northern Ireland) Order 1981, applies in Northern

 

Ireland. Therefore it is a requirement that fuels burnt or obtained for use in smoke control

 

areas have been "authorised" in Regulations and that appliances used to burn solid fuel in

 

those areas (other than "authorised" fuels) have been exempted by an Order made and signed

 

by the Secretary of State or Minister in the devolved administrations.

 

Further information on the requirements of the Clean Air Act can be found here :

 

http://smokecontrol.defra.gov.uk/

 

Your local authority is responsible for implementing the Clean Air Act 1993 including

 

designation and supervision of smoke control areas and you can contact them for details of

 

Clean Air Act requirements”

 

 

Содержание HHB4SE

Страница 1: ...ASE READ ALL THESE INSTRUCTIONS CAREFULLY For safety reasons it is essential that your stove is correctly installed and operated Hothouse cannot accept responsibility for any fault or consequential pr...

Страница 2: ...Connection to Chimney 4 Material Clearances 5 Hearths 5 Commissioning Handover 5 5 Technical Data 6 6 Operating Instructions 6 Air controls 6 Cleaning 7 Fuels 7 Notes on Wood Burning 7 Lighting the st...

Страница 3: ...tove assembly and controls Fig 2 HHB4SE Stove Assembly and controls Description of Parts Qty Hothouse Stove Assembly 1 Tool 1 Ash Pan 1 Flue Collar 1 Flue Collarfixing screws Washers 4 Legs 4 Stove Op...

Страница 4: ...rning This stove must notbe installed into a chimney that serves any other heating appliance Extractor Fan Warning There must not be an extractor fan fitted in the same room as the stove as this can c...

Страница 5: ...tal Parts When installing or servicing this stove proper care should be taken to avoid the possibility of personal injury 4 0 Installation Information Chimney The chimney height and the position of th...

Страница 6: ...that all connections between the stove and chimney flue are sealed and made airtight with sealing rope clamping rings and or fire cement or heat resisting cement where required Both the chimney and f...

Страница 7: ...provide much more or less than their rated heat outputs depending upon how they are burnt and fuels and fuel loads used On completion of the installation and commissioning ensure that the operating in...

Страница 8: ...mportant to use the rotary grate to de ash regularly to ensure that the primary airflow is not impeded as a build up of ash can damage the cast iron bed Ashpan It is essential that you empty the steel...

Страница 9: ...en Leave the door slightly ajar for 10 minutes to enhance initial starting and reduce smoke emission DO NOT leave the stove unattended if the door is left ajar Allow the fuel to reach a steady glow an...

Страница 10: ...ROUS Always use a fireguard in the presence of children the elderly or the infirm DO NOT perform modifications to the appliance as this could seriously compromise safety in operation DO NOT OVERFIRE i...

Страница 11: ...all air controls fully Move furniture and rugs away from the fireplace and remove any nearby ornaments Place a fireguard or spark guard in front of the stove Feel the chimneybreast for sign of excess...

Страница 12: ...attends any stove problem that is not related to product failure 6 Where can I get spare parts Your local Hothouse Stove retailer will be pleased to supply spare parts and to provide any other inform...

Страница 13: ...ireboard Y1HDF04D06E 28 Front Y1HDF04D34E 07 Side Plate Right fireboard Y1HDF04D07E 29 Base Y1HDF04D35E 08 Riddle Grate Y1HDD08E 30 Side Right Y1HDF04D36E 09 Grate for Riddle Grate Y1HDF04D12E 31 Side...

Страница 14: ...de Plate Right fireboard Y1HDF06D07E 28 Front Y1HDF06D34E 08 Riddle Grate Y1HDD09E 29 Base Y1HDF06D35E 09 Grate for Riddle Grate Y1HDF06D12E 30 Side Right Y1HDF06D36E 10 Grate Mounting Bracket Left Y1...

Страница 15: ...de Plate Right fireboard Y1HDF08D07E 28 Front Y1HDF08D34E 08 Riddle Grate Y1HDD09E 29 Base Y1HDF08D35E 09 Grate for Riddle Grate Y1HDF08D12E 30 Side Right Y1HDF08D36E 10 Grate Mounting Bracket Left Y1...

Страница 16: ...in a smoke control area unless it is used in an exempt appliance exempted from the controls which generally apply in the smoke control area The Secretary of State for Environment Food and Rural Affair...

Отзывы: