HOSSEVEN HBS-12 Скачать руководство пользователя страница 14

13 

 

 

In the various positions of thermostat button (1,2...7), thermostat opens and closes gas path 

according  to  temperature  in  the  environment,  where  stove  is  placed.  For  example,  when 
environment  temperature  is  17  C,  stove  opens  gas  path  in  approximately  in  3  position  and 
burner starts to burn. 

When the temperature, which is detected by thermostat end, is above the set temperature, 

main burner is turned off and only pilot is combusted. 

IMPORTANT NOTE: If your stove is not active in lower positions, this situation is the FEATURE 

OF THERMOSTAT, IT IS NOT FAILURE. 

 

8.1- Ignition  of pilot flame 
 

Turn on main gas valve. Bring thermostat button (*) to the position as shown in Figure-A2 

and press button. When button is pressed, hold it for 8-10 seconds, and at the same time you 
can  observe  pilot  flame  is  combusted  by  pressing  lighter  button.  You  can  observe  pilot  is 
combusted from windshield. For Hp-10 and HS-10; observe pilot flame is combusted by holding 
button in pressed position for 8-10 seconds. 

After pilot is combusted, hold thermostat button for 10 seconds. 
Pilot must continue combustion after release thermostat button. If pilot extinguishes, repeat 

above procedures. 

Especially in first combustion, your stove may be combusted late due to air inside of pipes. 
 

8-2 Adjustment of Ambiant  Temperature   
 

Bring  environment  temperature,  thermostat  button  to  the  desired  position  between 

minimum (1) and maximum (7) conditions in the counterclockwise. In the selected position in 
Figure-A3, thermostat will open main burner flame automatically and will control environment 
temperature. 

You can ensure maximum combustion by bringing thermostat position to the (7). 
You can ensure minimum combustion by bringing thermostat position to the (1-2). 
The  approximate  temperature  distribution  diagram  regarding  this  adjustment  is  shown  in 

TABLE-1. 

 

8-3 Extinguishing of the stove 
 

If your stove will not be used for a long time (full time) bring thermostat button to the (0) 

position. The pilot burner will extinguish. (Figure-A1) 

Repeat above mentioned operations (3.1) to combust your stove. 
If you will not use your stove for a short time (a few hours) bring thermostat button to the 

(*) position. Pilot will be active and it will be necessary to turn thermostat button to combust 
main burner. 

 

Содержание HBS-12

Страница 1: ...PLACE NATURAL GAS LPG STOVE INSTRUCTION MANUAL MODEL HERMETIC HDU 3 HERMETIC HDU 5 HERMETIC HDU 8 HERMETIC HDU 9 HERMETIC HDU 10 FUNNELED HBS 12 HBS 9 HERMETIC FIREPLACE HS 8 10 PLASMA FIREPLACE HP 3...

Страница 2: ...bles and special liquid Tighten hose terminations with clamp Do not put any container having liquids in it on your stove Attention failures causing from these reasons are not covered by this guarantee...

Страница 3: ...ction heaters UE 2016 426 Gas Appliance Regulation GAR 2011 65 EU Directive on the restriction of use of certain hazardous substance RoHS 2009 125 ECEcodesign requirements forenergy reletad products E...

Страница 4: ...on 10 6 2 Bottled gas LPG Connection 10 6 3 Gas Leakage Control 11 7 Commissioning of the device 12 8 Usage of device 12 8 1 Combustion of pilot 13 8 2 Adjusting Ambient Temperatures 13 8 3 Extinguish...

Страница 5: ...signed in order to complete decoration of your house 2 WARNING BEFORE INSTALLATION The specification published by Local Gas Distribution Company must be followed for the installation and the place whe...

Страница 6: ...e of location where hermetic kit holes are connected from wall must be as shown in the figure Figure 1 Stove mounting distances WARNING The specified fire protection distance as shown in the nstructio...

Страница 7: ...scopic flue kit At least 2 5 meters distance must be available between exhaust gas pipes in the building fa ade If stove will be mounted under the window the distance between lower edge of window and...

Страница 8: ...s outlet pipe of your stove is telescopic make distance adjustment according to this standard size Reinstall body to its place after make necessary connections and tests 5 VENTED STOVE FEATURES It is...

Страница 9: ...to the flue in an upward slope of 3 Adjust the part of pipe inside of flue as not to reduce flue draught Ensure sealing by closing the part of pipe inside of flue with non combustible material plaster...

Страница 10: ...ed and sealed connection for NG 8 mm hose for LPG Figure 7 Gas connection type Stove rolled out as natural gas adjusted or LPG adjusted To which gas your stove is adjusted is written on device or on p...

Страница 11: ...approved according to request of existing standards and local gas distribution companies before the installation Make competent engineers from gas distribution companies do this project Make authorize...

Страница 12: ...s leakage controls must be done with soap suds or special liquid Leakage control must be carried out in connecting elements between device and gas installation and joints ATTENTION Never make control...

Страница 13: ...ll be valid Guarantee Certificate is located in the back cover of this manual When gas smell is available in the environment where your device is located turn off gas valve tube and regulator is avail...

Страница 14: ...stat button for 10 seconds Pilot must continue combustion after release thermostat button If pilot extinguishes repeat above procedures Especially in first combustion your stove may be combusted late...

Страница 15: ...ice when it is cold Dry your device immediately after cleaning it with damp cloth Do not use any cleaning agent detergent for cleaning It is recommended to make control of your stove in each year and...

Страница 16: ...LPG G30 30 mbar Pilot Injector Burner Injector Pilot Injector Burner Injector HBS12 0 41 3 0 30 1 8 HHS9 0 41 2 5 0 30 1 6 HDU5 0 41 2 0 0 30 1 2 HDU8 0 41 2 5 0 30 1 6 HDU10 0 41 2 6 0 30 1 8 HDU 3 0...

Страница 17: ...4 14 IMPORTANT WARNINGS The issues regarding PRODUCT GUARANTEE CONDITIONS which must be paid attention by consumer Product Guarantee which is provided by Ho seven A does not cover defects and losses...

Страница 18: ...stove arising from changing operation settings which are compulsory to be adjusted by authorized service or changing operation parameter adjustments by unauthorized person are outside of guarantee sco...

Страница 19: ...0224 384 11 14 e mail hosseven hosseven com tr web www hosseven com tr 17 AUTHORIZED SERVICE CENTERS Customer Service Headquarter is the Ho seven Factory of which full address is given above Contact...

Страница 20: ...19 HDU 10 WALL MOUNTS SCHEME HDU 5 and HDU 3 WALL MOUNTS SCHEME Figure 9 Wall Mounts Scheme...

Страница 21: ...rate of defective goods or if possible to replacement with goods which is free from defects Ho seven evaluates this request If appropriate Ho seven meets consumer demands Ho seven A is responsible to...

Страница 22: ...cerning the Protection of Consumers Nr 4077 and the Regulation Concerning the Implementation Principles of the Guarantee Certificate enforced based on this law MANUFACTURER S OR PRODUCER S Title HO SE...

Страница 23: ...22...

Страница 24: ...ur device before our service our service carry out first run 2 Natural gas connection must be done by authorized dealer 3 Guarantee card must be approved for connection coupon will be valid 4 Product...

Страница 25: ...24 Authorized Service Seal and signature Customer Name Address Telephone Start up date 201 customer Signature First run of the machine is carried out by authorized service...

Страница 26: ...hey will be sent to Ho seven with service report by writing necessary information in possible failure cases Customer s Signature Note These coupons will be given to the customer with guarantee certifi...

Отзывы: