![HOSSEVEN HBS-12 Скачать руководство пользователя страница 11](http://html1.mh-extra.com/html/hosseven/hbs-12/hbs-12_instruction-manual_2165631011.webp)
10
WARNING:
The appliance can only be operated by gas family defined on the data label of
appliance.
Nominal values of gas supply pressure;
* For Natural Gas G20 / 20 mbar
* For LPG G30/30 mbar.
Allowed maximum gas pressure 50 mbar.
WARNING:
If the pressure of gas supply is higher than 50 mbar ,in this case using a gas
pressure
regulator
.
The
installation
must
comply
for
valid
standards.
Disregard of these instruction can result in death ,injury or property damage.
6.1 Natural Gas Connection
•
Make sure that the stove is adjusted for natural gas.
•
Connection of your stove to the natural gas must be prepared and approved according to
request of existing standards and local gas distribution companies before the installation.
•
Make competent engineers from gas distribution companies do this project.
•
Make authorized and qualified person/organizations do natural gas installations.
6.2 LPG Connection
•
If your stove is adjusted for LPG, pressure of 30mbar, at least 1,6 kg hour flow regulator
must be used in absolute way.
•
Regulator with the pressure of 50 mbar must be used.
•
In the usage of stove with LPG, it is recommended to use TSE approved 2 x 12 kg tube.
•
Otherwise, it will cause sufficient gas flow cannot be taken.
•
Tubes must be not placed cold and snowy environments and near furnace and oven.
•
Tubes must not be titled and not turn upside down
•
Damp cloth to the mouth of tube, when gas leak is formed for any reason.