II. Installation Instructions

A. Location

  CAUTION

This unit is not intended for outdoor use. The air temperature should be within 
a +45°F to +100°F (+7°C to +38°C) range. Extended periods of operation at 
temperatures exceeding these limitations may cause unsatisfactory results.

For best operating results:
• The machine should be on a flat, level and solid foundation.
• The unit should not be located in a corrosive environment.
• The unit should not be near ovens, grills or other high heat producing equipment.
• The unit should be a minimum of 4 inches (102 mm) from side walls. More clearance may 

be necessary depending on the door combination of the unit.

• A minimum of 10 inches (254 mm) overhead clearance should be provided for proper 

ventilation.

• Position unit for convenient usage of front and rear doors.

B. Checks Before Installation

IMPORTANT

Refer to the nameplate for electrical specifications. The nameplate is located 
on the right side wall of the cabinet interior. We reserve the right to make 
specification and design changes without prior notice.

1) All tape, packing material and shipping cartons should be removed from the machine 

prior to installation. The equipment should be inspected for any damage which may      
have occurred during shipment. Concealed damage claims must be filed with the 
carrier.

2) Visually check that the refrigerant lines do not rub or touch other lines or surfaces and 

that the fan blades turn freely.

3) Check that the compressor is snug on all mounting pads.
4) Remove all accessory containers before discarding the packing materials. Dispose of all 

packing materials in a proper and environmentally responsible manner.

5) To remove the unit from the skid:

(a) Move as close to the final location as possible.
(b) Remove the four 5/8 in. bolts that secure the cabinet to the skid.
(c) Block the cabinet securely, at a height of 8 inches (203 mm) off the floor. Do not lay 

the unit down.

(d) Attach the adjustable legs (or optional casters) to the bottom of the cabinet.

Содержание TempGuard PTR1SSB Series

Страница 1: ...Hoshizaki A Superior Degree of Reliability www hoshizaki com Models PTR1SSB xxxx TempGuard Pass Thru Refrigerator Hoshizaki America Inc Issued 9 19 2002 Revised 10 30 2006 INSTRUCTION MANUAL...

Страница 2: ...tenance and service of the unit Should the reader have any questions or concerns which have not been satisfactorily addressed please call write or send an e mail message to the HOSHIZAKI Technical Sup...

Страница 3: ...lation Instructions 6 A Location 6 B Checks Before Installation 6 C How to Open the Front Panel 7 D Setup 7 E Electrical Connection 7 F Door Reversing Stainless Steel Doors Only 7 G Final Checklist 8...

Страница 4: ...to make speci cation and design changes without prior notice MODEL NAME PTR1SSB xxxx SERIAL NUMBER AC SUPPLY VOLTAGE 115 60 1 AMPERES 12 0 DESIGN PRESSURE HI PSI 450 DESIGN PRESSURE LO PSI 250 REFRIG...

Страница 5: ...elf Space Depth with Doors Open 674 l 23 8 ft3 1 26 m2 13 6 ft2 Glass on both sides 2 146 2 mm 84 7 in Glass on one side and solid on the other 2 161 6 mm 85 3 in Solid on both sides 2 177 mm 85 9 in...

Страница 6: ...ions The nameplate is located on the right side wall of the cabinet interior We reserve the right to make speci cation and design changes without prior notice 1 All tape packing material and shipping...

Страница 7: ...lips at the same height E Electrical Connection Cord connected units should only be plugged into a 115 volt 10 60 Hz circuit with a national and local electrical code approved grounded wall receptacle...

Страница 8: ...ches 254 mm overhead clearance for proper ventilation 4 Have all shipping cartons tapes and packing materials been removed from the unit 5 Has the power supply been checked or tested against the namep...

Страница 9: ...value for the average cabinet temperature For example setpoint 36 F compressor on at 39 F compressor off at 33 F If necessary adjust the setpoint temperature as follows 1 Press and hold the up down a...

Страница 10: ...portant Note For the change to take effect you must cycle through the menu until you return to the normal display Note The change in the defrost setting will take effect after the next defrost based o...

Страница 11: ...t cloth Use a damp cloth containing a neutral cleaner to wipe off oil or dirt build up B Maintenance 1 Air Filter Check the lter at least once a month If it is dirty use warm water and a neutral clean...

Страница 12: ...service technician E4 6 beeps every ten seconds High Pressure Alarm Compressor discharge pressure is outside normal operating range Pressure switch has been triggered 3 or more times in 1 hour Press...

Страница 13: ...will reset During alarm press RESET to silence buzzer for 5 minutes CF 1 beep every ten seconds Clogged Filter Alarm Condenser lter needs cleaning Clean lter Allow time for sensor to react then press...

Страница 14: ...14 HOSHIZAKI AMERICA INC 618 Hwy 74 S Peachtree City GA 30269 USA TEL 770 487 2331 FAX 770 487 3360 www hoshizaki com 91A3GA10B...

Отзывы: