6
II. Installation Instructions
A. Location
CAUTION
This unit is not intended for outdoor use. The air temperature should be within
a +45°F to +100°F (+7°C to +38°C) range. Extended periods of operation at
temperatures exceeding these limitations may cause unsatisfactory results.
For best operating results:
• The machine should be on a flat, level and solid foundation.
• The unit should not be located in a corrosive environment.
• The unit should not be near ovens, grills or other high heat producing equipment.
• The unit should be a minimum of 4 inches (102 mm) from side walls. More clearance may
be necessary depending on the door combination of the unit.
• A minimum of 10 inches (254 mm) overhead clearance should be provided for proper
ventilation.
• Position unit for convenient usage of front and rear doors.
B. Checks Before Installation
IMPORTANT
Refer to the nameplate for electrical specifications. The nameplate is located
on the right side wall of the cabinet interior. We reserve the right to make
specification and design changes without prior notice.
1) All tape, packing material and shipping cartons should be removed from the machine
prior to installation. The equipment should be inspected for any damage which may
have occurred during shipment. Concealed damage claims must be filed with the
carrier.
2) Visually check that the refrigerant lines do not rub or touch other lines or surfaces and
that the fan blades turn freely.
3) Check that the compressor is snug on all mounting pads.
4) Remove all accessory containers before discarding the packing materials. Dispose of all
packing materials in a proper and environmentally responsible manner.
5) To remove the unit from the skid:
(a) Move as close to the final location as possible.
(b) Remove the four 5/8 in. bolts that secure the cabinet to the skid.
(c) Block the cabinet securely, at a height of 8 inches (203 mm) off the floor. Do not lay
the unit down.
(d) Attach the adjustable legs (or optional casters) to the bottom of the cabinet.