17
2. Condensing Unit
1) Remove the front panel.
) Connect the six wires from the icemaker to the condensing unit's terminal board. See
wiring label for wiring connections.
3) Supply power from the electrical panel to the condensing unit. (This differs from KM
style installations.) Connect the wire leads in the power supply junction box to the
power supplied from the disconnect or electrical panel.
Note: On single phase machines, the white lead must be attached to the neutral
conductor of the power source. Miswiring results in severe damage to the
icemaker. See Fig. 7.
CAUTION
Turn power supply on at condensing unit. Condensing unit should have power
for a minimum of 4 hours prior to startup to prevent compressor damage.
Fig. 7
WARNING
ELECTRICAL CONNECTION
The white lead must be connected
to the neutral conductor of the power
source.
Miswiring results in severe damage to
the icemaker.
(See Fig. below.)
08-30/60/1
(3 wire with neutral for 115V)
Power Supply
Junction Box
Brown
White
Black
L1
N
L
08-
30V
1
0-
1150V
G. Water Supply and Drain Connections
See Fig. 8
IMPORTANT
To prevent damage to the pump assembly, do not operate the icemaker when
the water supply is OFF, or if the pressure is below 10 PSIG.
• Water supply inlet is 1/" female pipe thread (FPT).
• A water supply line shut-off valve and drain valve should be installed. A minimum of 1/"
OD copper tubing is recommended for the water supply lines.
• Water supply pressure should be a minimum of 10 PSIG and a maximum of 113 PSIG. If
the pressure exceeds 113 PSIG, the use of a pressure reducing valve is required.