18
3. Controls and Adjustments
a) Default Dip Switch Settings
The dip switches are factory-adjusted to the following positions:
S4 Dip Switch
Dip Switch No.
1
3
4
5
6
7
8
9
10
KMS-130MLH ON OFF OFF ON ON ON ON OFF OFF ON
S5 Dip Switch (Do Not Adjust)
Dip Switch No.
1
3
4
5
KMS-130MLH OFF ON OFF OFF OFF
b) Harvest Timer (S4 dip switch 1 & 2)
The harvest timer starts counting when the thermistor reads 48°F (9°C) at the evaporator
outlet. No adjustment is required under normal use, as the harvest timer is adjusted to
the suitable position. Before changing this setting, call the HOSHIZAKI Technical Support
Department at 1-800-33-1940 for recommendations. Keep in mind that setting the
harvest timer to a longer setting will decrease 4 hour production.
Dip Switch Setting
Time
(seconds)
No. 1
No.
OFF
OFF
60
ON
OFF
90
OFF
ON
10
ON
ON
180
S4 Dip Switch
Freeze Timer (9 & 10)
Pump-Out Frequency Control (5 & 6)
Pump-Out Timer (3 & 4)
Harvest Timer (1 & )
Normally in the OFF position (8)
Do not adjust (7)