Hoshizaki
©
HOSHIZAKI AMERICA, INC.
URC-F/SRC-H/SRK-H
REMOTE CONDENSER SERIES
AIR-COOLED
28-1/4"
(717mm)
Liquid Refrigeration Line Fitting
Suction Refrigeration Line Fitting
Electrical Supply Hole
2-
13
/32
"
(6
1m
m)
14
-3
1/3
2"
(3
80
mm
)
6-15/32"
(64mm)
2-3/4"
(70mm)
11-3/4"
299mm)
2-
11
/16
"
(6
8m
m)
19
-2
9/3
2"
(5
06
mm
)
R E M OT E A I R - C O O L E D
O P E R AT I N G L I M I T S
U R C - 5 F / U R C - 6 F / U R C - 9 F
U R C - 1 2 F / U R C - 1 4 F / U R C - 2 0 F / U R C - 2 1 F
• Ambient Temp Range
-20 - 122˚F
• Voltage Range
104 - 127V
O P E R AT I N G L I M I T S
S R K - 7 H / S R C - 1 0 H / S R K - 1 4 H / U R C - 2 4 F
• Ambient Temp Range
-4 - 122˚F / -22 - 122˚F
• Voltage Range
187 - 253V
E L E C T R I C A L
U R C - 5 F / U R C - 6 F / U R C - 9 F
U R C - 1 2 F / U R C - 1 4 F / U R C - 2 0 F / U R C - 2 1 F
• 115V/60/1 (Connection to icemaker)
E L E C T R I C A L
S R K - 7 H / S R C - 1 0 H / S R K - 1 4 H / U R C - 2 4 F
• 208-230V/60/1 (Connection to icemaker)
618 Hwy. 74 S., Peachtree City, GA 30269
TEL 1-800-438-6087
FAX 1-800-345-1325
www.hoshizaki.com
Printed in U.S.A.
R E M O T E C O N D E N S E R I N S T A L L A T I O N O N R O O F
For best performance allow 24 inch clearance for air circulation
For best performance
the Remote Condenser
should not be more
than 33 feet above the
KM Icemaker or no
more than 10 feet below
it. Thes distances are
measured from fitting to
fitting.
Electrical Conduit Access
Air Flow
Discharge Line
Liquid Refrigerant Line
Discharge line
Liquid refrigerant line
Icemaker and Storage Bin
sold separately
ICEMAKER
ICE STORAGE BIN
Model Number
Air-Cooled
Condenser
55’ length
35’ length
20’ length
Order Tubing Kits Separately
Shipping
Weight
URC-12F
R404-2068-2 R404-3568-2 R404-5568-2 110 lbs.
URC-20F
R404-20610 R404-35610 R404-55610
145 lbs.
URC-21F
R404-20610 R404-35610 R404-55610
165 lbs.
SRC-10H
R404-20410 R404-35410 R404-5510
180 lbs.
2
1/2
inch Diameter hole in roof for tubing.
Seal after installation to prevent leaking.
Electrical connections must
meet all local codes.
Remote Condenser
fan motor connection
Electrical
conduit
access
1
3/4
21
24
18
1/8
2
1/2
14
11/16
32
13/16
18
3
3/8
Discharge line
1/4
Liquid
refrigerant line
URC-5F / URC-6F
24 x 18
1/8
x 32
13/16
W x D x H
Electrical conduit
access
2
3/4
35
11/16
37
13/16
18
1/8
2
3/4
14
11/16
22
37
3
1/2
Discharge line
3/8
Liquid
refrigerant line
URC-12F / URC-14F
37
13/16
x 18
1/8
x 37
W x D x H
SRC-10H
30
1/4
x 25
3/8
x 34
7/8
W x D x H
Electrical
conduit
access
2
3/4
18
1/8
2
3/4
15
11/16
46
3/8
26
48
7/16
40
7/8
3
5/8
Discharge line
3/8
Liquid
refrigerant line
URC-20F
48
7/16
x 18
1/8
x 40
7/8
W x D x H
Electrical conduit
access
12
1/2
43
3/4
15
5/8
19
3/4
9
3/4
36
5/8
Discharge line
3/8
Liquid refrigerant line
URC-24F
43
3/4
x 19
3/4
x 36
1/32
W x D x H
• URC-5F
• SRC-10H
• URC-20F
• URC-6F
• URC-12F
• URC-21F
• SRK-7H
• SRK-14H
• URC-24F
• URC-9F
• URC-14F
URC-24F
R404-20610 R404-35610 R404-55610
210 lbs.
URC-6F
R404-2046-2 R404-3546-2
N/A
60 lbs.
Electrical
conduit
access
2
3/4
18
1/8
2
3/4
15
11/16
46
3/8
26
48
7/16
40
7/8
3
5/8
Discharge line
3/8
Liquid
refrigerant line
URC-21F
48
7/16
x 18
1/8
x 40
7/8
W x D x H
URC-14F
R404-2068-2 R404-3568-2 R404-5568-2 110 lbs.
URC-5F
R404-2046-2 R404-3546-2
N/A
60 lbs.
Pre-Charged Tubing Kits
(Sold Separately)
Refer to SPECIFICATIONS
table to determine appropriate
Tubing Kit Number for Remote
Condenser Unit specified.
Electrical
conduit
access
2
1/2
18
1/8
2
11/16
15
11/16
32
3/16
21
15/16
34
5/16
36
15/16
3
3/8
Discharge line
1/4
Liquid
refrigerant line
URC-9F
34
5/16
x 18
1/8
x 36
15/16
W x D x H
SRK-7H / SRK-14H
52
3/8
x 19
1/2
x 43
W x D x H
43
52
3/8
19
1/2
Liquid Ref. Line
Suction Ref. Line
Electrical Supply
7/8” Dia.Opening
SRK-14H
R404-20810 R404-35810 R404-55810
273 lbs.
SRK-7H
R404-20810 R404-35810 R404-55810
240 lbs.
URC-9F
R404-2068-2 R404-3568-2 R404-5568-2
95 lbs.