12
B. Startup
CAUTION
All parts are factory adjusted. Improper adjustments may result in failure or loss
of product.
Supply power to the unit. Open the front panel for access to the power switch—located
on the front of the control box—and move the switch to the "ON" position. Allow the unit
to pull down prior to loading it with food products.
IMPORTANT
• TempGuard Refrigerators and Freezers: At startup, there is a 2 1/2 minute
delay before the compressor starts.
Note: On Dual Temp units, there is a delay of approximately 10 seconds
between one compressor start (i.e. freezer) and the next compressor
start (i.e. refrigerator).
• SafeTemp Refrigerators: At startup, there is a 2 minute delay before the
compressor starts.
• SafeTemp Freezers: At startup, a defrost is initiated.
C. Cabinet Temperature
1. TempGuard Models
a) Temperature Display
• The cabinet temperature is displayed on the control panel. See Fig. 7. The display
default is °F, but it can be changed to read °C. To change, see "II.C.1.c) Changing the
Temperature Display Scale (°F or °C)".
• The cabinet temperature is updated every 20 seconds.
Front Panel
Control
Panel
Door
Arrow
Fig. 7