DISCONNECT UNIT FROM POWER SUPPLY BEFORE DOING ANY SERVICE
Instructions to Replace Compressor.
14. Remove the four nuts
that hold in place the
compressor to the base
rails using a 7/16”
socket ratchet.
15. Remove the
compressor from the
base rails.
16. Not all compressor removal
requires cleaning the low and high
sides of the system. However, if
you suspect that there are high
levels of contamination, sweep
the system using dry nitrogen at
250 psig.
17. Place the new
compressor on the
base rails