DISCONNECT UNIT FROM POWER SUPPLY BEFORE DOING ANY SERVICE
Instructions to Replace Compressor.
10 . The first step is to recover all
refrigerant from the system by
installing a piercing valve in the
compressor service tube.
Attach the hose of the recovery
machine to the service tubing. Use
an Allen Key Wrench to close the
piercing valve for piercing the tube
and open it to release the
refrigerant.
11. Open Manifold Gauge
Pressure valves and
turn on the recovery
machine to recover all
the refrigerant.
12. Warm the brazing of
the discharge and
suction tubes in order
to unsolder them from
the compressor.
13. To remove the filter
dryer, slowly warm up
the joint of the
capillary tubing with
the filter dryer and pull
them apart by using
pliers.