13. Trouble Shooting 

SYMPTOMS 

POSSIBLE CAUSES 

CHECKS AND SOLUTIONS

The machine does not 
work. 
 

No power 
 
 
 
 
 
 
 
No water in the tank 

Check the electrical system 
 
Check that the electrical plug is 
inserted in the socket outlet 
 
That the electrical socket outlet is 
turned on 
 
Add water to the tank 

The refrigerator does 
not cool (the fan, 
compressor and 
agitator motor work). 
 

No refrigerating gas 

Check refrigerator circuit pressure 
and possible leaks 
 
Recharge with gas 

The refrigerator works, 
the agitator/pump 
motor is stopped. 

No power to agitator/pump motor 
 
 
 
 
Agitator/pump motor failure 

Check the electrical system 
 
Check the motor plug is plugged in 
 
 
Replace agitator/pump motor 

The refrigerator does 
not cool (the fan and 
compressor and agita-
tor/pump motor work). 

Thermostat or thermostat probe 
do not work. 
 
 
 
 

No water in the tank

 

Check thermostat electrical 
connections 
 
Check the motor plug is plugged in 
 
 
Add water to the tank 

The refrigerator does 
not cool; the compres-
sor is stopped (the fan 
and agitator/pump mo-
tor work). 

No power to compressor 
 
 

Compressor failure

 

Check terminal board connection 
Check the clixon overload and relay 
 
Replace the compressor 

The refrigerator never 
stops and freezes the 
beverage 

Thermostat or probe failure 

Replace the thermostat or probe 

The refrigerator does 
not cool (the fan is 
stopped, the 
compressor and 
agitator/pump motor 
work) 

No power to the fan motor 
 
 
 

Motor fan failure

 

Check the electrical system 
Check terminal board connection 
 
 
Replace motor fan 
 

The agitator motor is 
noisy 

Ball bearing fault 
 
Worn bushings 

Replace agitator motor pump 
 
Replace agitator motor pump 

 

Содержание Lancer Mini Lady

Страница 1: ...lancerbeverage com Installation Operation Service Manual Mini Lady 240V 50Hz...

Страница 2: ...chine 6 7 2 Proper uses 6 7 3 Improper uses 6 8 Transportation 7 8 1 Packaging 7 8 2 Transport and handling with packaging 7 8 3 Storage of the machine with packaging 7 8 4 Receiving 7 8 5 Unpacking 7...

Страница 3: ...ated in Adelaide SA with branch offices and warehousing facilities in Sydney NSW Melbourne VIC Brisbane QLD Perth WA and Auckland New Zealand 3 Our Products Lancer specialises in the design engineerin...

Страница 4: ...res Housing Stainless Steel Coils Stainless Steel Ice bank Control Electronic Cooling Capacity 25 Lt hr 5 Safety Information 5 1 Safety Instructions For your personal safety and that of others working...

Страница 5: ...ppliance is not suitable for installation in an area where a water jet could be used Caution This appliance is not intended for use by persons including children with reduced physical sensory or menta...

Страница 6: ...ed and fully aware of all the information and prescriptions contained in the documentation supplied Only original spare parts guarantee the functional reliability and optimisation of the machine s per...

Страница 7: ...The machine must be stored in a humidity free room and the machine must not be exposed to bad weather Never stack more than two machines on top of another 8 4 Receiving Each unit is completely tested...

Страница 8: ...taps using a suitable liquid detergent D Repack the machine in its original packaging 10 Installation and Adjustment Warning To avoid personal injury or damage do not attempt to lift a Chiller without...

Страница 9: ...ted to the supply via a 10 amp flexible cord fitted with a 3 pin plug Check the name plate on the machine for electrical supply requirements Use only the power supply specified on the name plate Warni...

Страница 10: ...of water 11 3 Checking efficiency Make sure that the motor fan is free from any filaments and dust Make sure that the motor stirrer has no scaling due to the water limestone Remove any scaling 12 Main...

Страница 11: ...motor plug is plugged in Replace agitator pump motor The refrigerator does not cool the fan and compressor and agita tor pump motor work Thermostat or thermostat probe do not work No water in the tank...

Отзывы: