background image

14

5a) 

Dispenser Unit:

 Follow the dispenser unit's instructions for securing the icemaker to 

the dispenser unit. If no instructions are available, secure the icemaker to the dispenser 
unit using the mounting brackets provided. Rotate the mounting brackets so that 
they fit flush to the dispensing unit. See Fig. 6a. Secure the mounting brackets to the 
icemaker with the bolts provided. Secure the mounting brackets to the dispensing unit 
with self-tapping screws (not provided). 

NOTICE!

 Use care to avoid damage to the 

dispenser unit components when attaching the mounting brackets. 

Seal the outer 

perimeter of the icemaker to the dispenser unit with RTV-748 sealant (provided) or 
equivalent. 

5b) 

Storage Bin: 

Secure the icemaker to the storage bin using the 2 mounting brackets and 

the bolts provided. See Fig. 6b. Seal the outer perimeter of the icemaker to the storage 
bin with RTV-748 sealant (provided) or equivalent. 

6) Level the icemaker and dispensing unit/storage bin in both the left-to-right and 

front-to-rear directions. If using a storage bin, adjust the storage bin legs to make the 
icemaker level.

Dispenser Unit Application

Storage Bin Application

Mounting 
Brackets

Bolts

Dispenser 
Unit

Storage Bin

Fig. 6a

Fig. 6b

Icemaker

Icemaker

Mounting 
Brackets

Bolts

Self-Tapping 
Screws 
(Not Provided)

Seal the Outer Perimeter with 

RTV-748 Sealant or Equivalent

Содержание KMS-1402MLJ

Страница 1: ...Models KMS 1402MLJ Including Condensing Unit Models SRK 15J 3 Modular Crescent Cuber Serenity Series Instruction Manual Issued 1 22 2018 Revised 3 6 2018 hoshizakiamerica com...

Страница 2: ...per installation is the responsibility of the installer Product failure or property damage due to improper installation is not covered under warranty Hoshizaki provides this manual primarily to assist...

Страница 3: ...densing Unit 19 1 Setup 19 2 Line Set 19 3 Line Set Installation 20 F Electrical Connection 22 G Water Supply and Drain Connections 25 H Final Checklist 27 I Startup 28 III Maintenance 30 A Maintenanc...

Страница 4: ...Move the control switch to the OFF position and turn off the power supply to the remote condensing unit before servicing Place the icemaker disconnect if applicable in the OFF position Lockout Tagout...

Страница 5: ...e for electrical specifications Failure to use an independent power supply of proper capacity can result in a tripped breaker blown fuse damage to existing wiring or component failure This could lead...

Страница 6: ...sure HI 467PSI LO 230PSI Total Refrigerant Charge 404A Total Refrigerant Charge with Hoshizaki Remote Condensing Unit SRK 15J 3 16 LB 5 OZ 2 SRK 15J 3 Model Number SRK 15J SRK 15J3 AC Supply Voltage 2...

Страница 7: ...Allow 6 15 cm clearance at rear sides and top for proper air circulation and ease of maintenance and or service should they be required The ice storage bin opening must match the bottom opening as in...

Страница 8: ...8 2 SRK 15J 3 Unit mm in Note Legs are included with remote condensing unit Leg height is 380 mm 14 96 in Top Side Front...

Страница 9: ...emaker NOTICE This icemaker is not intended for outdoor use Normal operating ambient temperature must be within 45 F to 100 F 7 C to 38 C Normal operating water temperature must be within 45 F to 90 F...

Страница 10: ...sing unit and the icemaker is greater than 20 feet not to exceed 33 feet an S oil trap 5 8 OD copper tubing must be installed in the suction line The S oil trap must be located halfway between the ice...

Страница 11: ...e film after the icemaker cools Check that the refrigerant lines do not rub or touch lines or other surfaces This icemaker can be installed on a dispenser unit or storage bin 30 wide or wider For opti...

Страница 12: ...II D 2 Water Tank Removal Fig 4 Top Panel Right Side Panel Louver Panel Front Panel Remote Condensing Unit Right Side Panel Fig 3 Top Panel Front Panel Insulation Panel Icemaker 2 Remote Condensing Un...

Страница 13: ...4 adjustable legs provided bin accessory to the bottom of the storage bin 2 Position the dispenser unit storage bin in its permanent location 3a Dispenser Unit Install the dispenser unit adapter kit...

Страница 14: ...s Seal the outer perimeter of the icemaker to the dispenser unit with RTV 748 sealant provided or equivalent 5b Storage Bin Secure the icemaker to the storage bin using the 2 mounting brackets and the...

Страница 15: ...ough the back of the icemaker If care is not taken when removing the water tank the bin control cable could be severed Pump Suction Hose Drain Pipe Water Tank Drain Hose Float Connection Hose Splash C...

Страница 16: ...uivalent Otherwise water leakage may occur which could result in a slip hazard and costly water damage Contact points between the dispenser unit and the dispenser unit adapter kit Contact points betwe...

Страница 17: ...using the 2 thumbscrews from the accessory bag Route the bin control cable from the outer corner of the bin control up through the gap in the extension bracket 4 Using the 2 thumbscrews removed in st...

Страница 18: ...ge the bin control Dispenser Unit Slide the bin control assembly all the way back until the switch mount is flush with the dispenser unit bin wall Storage Bin Slide the bin control assembly all the wa...

Страница 19: ...e to equipment The maximum line set length is 66 feet and no refrigerant charge adjustment is necessary NOTICE Do not exceed maximum line set length Line Set Size and Length for SRK 15J 3 Remote Conde...

Страница 20: ...to allow the icemaker to be pulled out for service See Fig 14 Note The service loop is not considered an oil trap 2 Remove any extra line set length 3 NOTICE Before brazing remove the Schrader valve...

Страница 21: ...rt is available at 1 800 233 1940 for recommendations Fig 14 Suction Line S Oil Trap Max 33 Feet Max 16 5 Feet Max 16 5 Feet Remote Condensing Unit with compressor Bin Icemaker Service Loop Max 10 Fee...

Страница 22: ...to meet these code requirements could result in death electric shock serious injury fire or damage The remote condensing unit requires an independent power supply of proper capacity See the nameplate...

Страница 23: ...the transformer s voltage tap switch must be positioned to match incoming voltage at startup NOTICE On three phase models connect the highest incoming voltage supply stinger leg to the power wire ded...

Страница 24: ...gend GND ground HGV hot gas valve CB control board LLV liquid line valve Wire Color Code BK black BR brown GR green P pink V violet W white KMS Icemaker Fuse 10A Icemaker Remote Condensing Unit Wire B...

Страница 25: ...be required in some areas External filters strainers or softeners may be required depending on water quality Contact your local Hoshizaki distributor for recommendations Water supply pressure should b...

Страница 26: ...is 5 8 OD hard tube The condensation drain line can be connected to the icemaker drain line or can be run separately Fig 17 KMS 1402MLJ Icemaker Water Supply Inlet 1 2 FPT Icemaker Water Supply Line S...

Страница 27: ...et all national state and local code and regulation requirements 8 Has the power supply voltage been checked or tested against the nameplate rating Has a proper ground been installed to the remote con...

Страница 28: ...k to fill with water and the icemaker to operate for a total of 10 minutes 5 After 10 minutes of operation confirm bin control operation Remove the front panel then press and hold the bin control s ac...

Страница 29: ...the ICE position 16 Replace the front panel in its correct position 17 Turn on the power supply to start the automatic icemaking process Pump Suction Hose Drain Pipe Water Tank Drain Hose Float Conne...

Страница 30: ...iance s environment and local sanitation regulations Maintenance Schedule Frequency Area Task Daily Scoop Clean the ice scoop using a neutral cleaner Rinse thoroughly after cleaning Monthly External W...

Страница 31: ...prevent damage to the water pump seal do not operate the icemaker with the control switch in the SERVICE position when the water tank is empty 1 Cleaning Procedure 1 Dilute 22 fl oz 650 ml of Hoshizak...

Страница 32: ...eir correct positions 12 Turn on the power supply to start the washing process 13 Turn off the power supply after 30 minutes Remove the front panel 14 Move the service switch to the DRAIN position 15...

Страница 33: ...start the sanitizing process 7 Turn off the power supply after 15 minutes Remove the front panel 8 Move the service switch to the DRAIN position 9 Replace the front panel in its correct position then...

Страница 34: ...l board should be on 6 Once LED 1 and 2 on the control board energize the order of the LEDs from the outer edge of the control board is 1 4 3 2 close the inlet water supply line shut off valve and ope...

Страница 35: ...pump connector 20 Close the inlet water supply line drain valve 21 Remove all ice from the dispenser unit storage bin and clean the dispenser unit storage bin liner using a neutral cleaner Rinse thoro...

Страница 36: ...sal The appliance contains refrigerant and must be disposed of in accordance with applicable national state and local codes and regulations Refrigerant must be recovered by properly certified service...

Страница 37: ...37 618 Hwy 74 South Peachtree City GA 30269 USA P 770 487 2331 F 770 487 3360 hoshizakiamerica com 1A5034 010...

Отзывы: