9) Attach the new thermistor to the suction pipe in the same position as the previous
thermistor. Be very careful to prevent damage to the leads. Secure it using the
thermistor holder and recommended foam insulation.
10) Secure the insulation using the plastic cable ties.
11) Connect the thermistor leads through the bushing of the control box to the K3 connector
on the control board.
Note: Do not cut the leads of the thermistor while installing it.
12) Replace the control box cover and the panels in their correct positions.
13) Turn on the power supply.
J. Removal and Replacement of Fan Motor
Note: When replacing a fan motor with defective winding, it is recommended that a new
capacitor be installed.
1) Turn off the power supply.
2) Remove the panels.
3) Remove the junction box cover from the remote condenser unit (remote air-cooled
model).
4) Remove the closed end connectors from the fan motor leads.
5) Remove the fan motor bracket and fan motor.
6) Install the new fan motor, and replace the removed parts in the reverse order of which
they were removed.
7) Replace the panels in their correct positions.
8) Replace the junction box cover in its correct position (remote air-cooled model).
9) Turn on the power supply.
K. Removal and Replacement of Water Valves
1) Turn off the power supply.
2) Close the water supply line shut-off valve.
3) Remove the panels.
4) Remove the tubing attached to the valve. If replacing the inlet water valve, loosen the
fitting nut. Be careful not to lose the washer.
5) Disconnect the terminals from the water valve.
6) Remove the bracket and valve from the unit.
7) Install the new water valve. Replace the removed parts in the reverse order of which
they were removed. If replacing the inlet water valve, make sure the washer is in place
in the fitting nut.
8) Open the water supply line shut-off valve.
9) Turn on the power supply.
10) Check for leaks.
11) Replace the panels in their correct positions.