![Hoshizaki KMD-450MAH Скачать руководство пользователя страница 61](http://html1.mh-extra.com/html/hoshizaki/kmd-450mah/kmd-450mah_service-manual_2164771061.webp)
61
K. Removal and Replacement of Fan Motor (air-cooled and remote
air-cooled models)
Note: When replacing a fan motor with defective winding, it is recommended that a new
capacitor be installed.
1) Turn off the power supply.
2) Remove the panels.
3) Remove the junction box cover from the remote condenser unit (remote air-cooled
model).
4) Disconnect the fan motor wires and the capacitor wires.
5) Remove the fan motor bracket, fan motor, and capacitor.
6) Install the new fan motor and capacitor onto the fan motor bracket. Install the assembly
into the icemaker and connect the fan motor and capacitor wires. Make sure the wires
are properly routed in the wire saddles and do not interfere with the fan blade.
7) Replace the panels in their correct positions.
8) Replace the junction box cover in its correct position (remote air-cooled model).
9) Turn on the power supply.
L. Removal and Replacement of Water Valves
1) Turn off the power supply.
2) If replacing the inlet water valve, close the icemaker water supply line shut-off valve.
Open the icemaker water supply line drain valve.
3) Remove the panels.
4) Disconnect the tubing attached to the valve. If replacing the inlet water valve, loosen
the fitting nut. Be careful not to lose the washer.
5) Disconnect the terminals from the valve.
6) Remove the bracket (if applicable) and valve from the unit.
7) Install the new valve. Replace the removed parts in the reverse order of which they
were removed. If replacing the inlet water valve, make sure the washer is in place in
the fitting nut.
8) If replacing the inlet water valve, close the icemaker water supply line drain valve. Open
the icemaker water supply line shut-off valve.
9) Turn on the power supply.
10) Check for leaks.
11) Replace the panels in their correct positions.