Problem
Possible Cause
Remedy
[4] Water continues to
be supplied in freeze
cycle.
a) Water Pressure
1. Too high.
1. Reduce.
b) Inlet Water Valve
1. Diaphragm does not
close.
1. Check for water leaks with
icemaker off.
c) Control Board
1. Defective.
1. See "IV.B. Control Board
Check."
[5] Pump motor will not
start.
a) Pump Motor
1. Motor winding open.
1. Replace.
2. Bearing worn out.
2. Replace.
3. Wiring to pump motor. 3. Check for loose
connection or open, and
replace.
4. Defective capacitor.
4. Replace.
5. Defective or bound
impeller.
5. Replace and clean.
b) Control Board
1. Defective.
1. See "IV.B. Control Board
Check."
c) Control Switch
1. Bad contacts.
1. Replace.
[6] Freeze cycle time is
too short.
a) Drain Valve
1. Leaking by.
1. Clean or replace.
b) Float Switch
1. Dirty or erratic
operation.
1. See "IV.D. Float Switch
Check and Cleaning."
c) Control Board
1. Defective.
1. See "IV.B. Control Board
Check."
d) Water System
1. Water leaks.
1. Check connections for
water leaks and repair.
[7] Fan motor will
not start, or is not
operating (except
water-cooled model).
a) Fan Motor
1. Motor winding open.
1. Replace.
2. Bearing worn out.
2. Replace.
3. Wiring to fan motor.
3. Check for loose
connection or open, and
replace.
4. Defective capacitor.
4. Replace.
5. Fan blade bound.
5. Check and replace.
b) Control Board
1. Defective.
1. See "IV.B. Control Board
Check."
[8] All components
run, but no ice is
produced.
a) Refrigerant
1. Low charge.
1. Check for leaks. Recover,
repair, evacuate, and
recharge.
2. Air or moisture
trapped.
2. Recover, replace drier,
evacuate, and recharge.
b) Compressor
1. Defective.
1. Replace.
c) Hot Gas Valve
1. Continues to open in
freeze cycle.
1. Check and replace.
d) Liquid Line Valve
(if applicable)
1. Continues to close in
freeze cycle.
1. Check and replace.
e) Inlet Water Valve
1. Inlet water valve is
wide open during
freeze.
1. Check for water leaks with
icemaker off.
f) Expansion Valve
1. Bulb loose.
1. Secure bulb.
2. Operating erratically.