5) The Water Supply Pipe is located right under the Spray Tube. Remove the Water
Supply Pipe from the Evaporator, pinch and shift the Hose Clamp, and disconnect
the Hose.
6) The Spray Guide is located under the Water Supply Pipe. Pull off the Spray Guide
from the Evaporator Plate.
7) Refit the removed parts in the reverse order of the removal procedure. Check for
water leaks.
IMPORTANT
Fit the Spray Guide securely and tightly on the Evaporator fin. Otherwise,
cloudy or irregular ice cubes or performance reduction may be caused.
8) Plug in the icemaker or connect the power source.
19. DOOR
1) Remove the Top Panel.
2) Remove the two mounting screws and the Brace.
3) Move the Door to fit the Door Shaft in the inlet of the Door Channel. Slide up the
Door to release it from the Door Channel.
4) Refit the Door in the reverse order of the removal procedure. Do not forget to fit the
Collar on the Door Shaft, or the Door will not open or close smoothly.
Mounting Screw
Brace
2
1
Fig. 28
Содержание KM-40B
Страница 1: ...KM 40B KM 55B KM 80B SELF CONTAINED CRESCENT CUBER SERVICE MANUAL F120 1011 073117 ...
Страница 5: ...1 I SPECIFICATIONS 1 DIMENSIONS SPECIFICATIONS a KM 40B Europe ...
Страница 6: ...2 b KM 40B Singapore ...
Страница 7: ...3 c KM 40B Australia New Zealand ...
Страница 8: ...4 d KM 40B Philippines ...
Страница 9: ...5 e KM 55B Europe ...
Страница 10: ...6 f KM 55B Singapore ...
Страница 11: ...7 g KM 55B Australia New Zealand ...
Страница 12: ...8 h KM 55B Philippines ...
Страница 13: ...9 i KM 80B Europe ...
Страница 14: ...10 j KM 80B Singapore ...
Страница 15: ...11 k KM 80B Australia New Zealand ...
Страница 16: ...12 l KM 80B Philippines ...
Страница 22: ...18 ...
Страница 37: ...33 2 WIRING DIAGRAM a KM 40B Philippines b KM 40B Except Philippines KM 55B ...
Страница 38: ...34 c KM 80B ...