34
I. Startup
WARNING
All parts are factory-adjusted. Improper adjustments may adversely affect safety,
performance, component life, and warranty coverage.
NOTICE
• If the icemaker is turned off, wait for at least 3 minutes before restarting the
icemaker to prevent damage to the compressor.
• To prevent damage to the water pump seal, do not leave the control switch in the
"WASH" position for extended periods when the water tank is empty.
• At startup, confirm that all internal and external connections are free of leaks.
Additional Notice for Remote Models
• The icemaker must have power for a minimum of 4 hours prior to startup to
prevent compressor damage.
1) Open the water supply line shut-off valve(s).
2) Remove the front panel.
3) Move the control switch on the control box to the "ICE" position.
4) Replace the front panel in its correct position.
5) Turn on the power supply, and allow the icemaker to operate for a total of 10 minutes.
6) Turn off the power supply, then remove the front panel.
7) Remove the base cover, then disconnect one end of the pump tubing to drain the water
tank. See Fig. 18.
8) After the water tank has drained, reconnect the pump tubing.
9) Clean the dispenser unit/ice storage bin liner using a neutral cleaner. Rinse thoroughly
after cleaning.
10) Replace the base cover and the front panel in their correct positions.
11) Turn on the power supply to start the automatic icemaking process.
12) During the first 5 minutes of the freeze
cycle, confirm bin control operation by
pressing and holding the bin control's
actuator paddle until the icemaker shuts
down. The icemaker should shut down in
approximately 15 seconds.
13) On water-cooled models, confirm proper
condenser drain outlet/return outlet
temperature as outlined in
"II.F.2. Water-Cooled Condenser."
Fig. 18