7
I. Specifications
A. Electrical and Refrigerant Data
The rating label and nameplate provide electrical and refrigerant data. The rating label
can be seen by removing the front panel. The nameplate is located on the rear panel. For
certification marks, see the nameplate.
We reserve the right to make changes in specifications and design without prior notice.
1. KM-1301S_J(Z)/3
Single Phase
Model Number
KM-1301SAJ
KM-1301SWJ
KM-1301SRJZ
AC Supply Voltage
208-230/60/1
208-230/60/1
208-230/60/1
Compressor
230V 10.0RLA 61LRA
230V 8.8RLA 56LRA
230V 9.3RLA 56LRA
Pump
120V 1.2FLA 60W
120V 1.2FLA 60W
120V 1.2FLA 60W
Fan
115V 1.0FLA 1/15HP
--- --- ---
120V 3A MAX (Fans in URC)
Other
115V 0.3A
115V 0.3A
115V 0.3A
Maximum Fuse Size 20 AMPS
20 AMPS
20 AMPS
Max. HACR Breaker
(USA Only)
20 AMPS
20 AMPS
20 AMPS
Max. Circuit Breaker
(Canada Only)
20 AMPS
20 AMPS
20 AMPS
Minimum Circuit
Ampacity
20 AMPS
20 AMPS
20 AMPS
Design Pressure
HI-467PSI LO-230PSI
HI-427PSI LO-230PSI
HI-467PSI LO-230PSI
Refrigerant
404A 4 LB. 3 OZ.
404A 2 LB. 2.4 OZ.
404A
Total Refrigerant Charge with
Hoshizaki Remote Condenser
Unit URC-14FZ: 10 LB. 5.8 OZ.
Three Phase
Model Number
KM-1301SAJ3
KM-1301SWJ3
KM-1301SRJZ3
AC Supply Voltage
208-230/60/3
208-230/60/3
208-230/60/3
Compressor
230V 7.1RLA 55LRA
230V 6.5RLA 51LRA
230V 6.2RLA 51LRA
Pump
120V 1.2FLA 60W
120V 1.2FLA 60W
120V 1.2FLA 60W
Fan
115V 1.0FLA 1/15HP
--- --- ---
120V 3A MAX (Fans in URC)
Other
115V 0.3A
115V 0.3A
115V 0.3A
Maximum Fuse Size 20 AMPS
20 AMPS
20 AMPS
Max. HACR Breaker
(USA Only)
20 AMPS
20 AMPS
20 AMPS
Max. Circuit Breaker
(Canada Only)
20 AMPS
20 AMPS
20 AMPS
Minimum Circuit
Ampacity
20 AMPS
20 AMPS
20 AMPS
Design Pressure
HI-467PSI LO-230PSI
HI-427PSI LO-230PSI
HI-467PSI LO-230PSI
Refrigerant
404A 4 LB. 3 OZ.
404A 2 LB. 2.4 OZ.
404A
Total Refrigerant Charge with
Hoshizaki Remote Condenser
Unit URC-14FZ: 10 LB. 5.8 OZ.