29
f) Wash Tank Thermistor Error (H1, H2)
Z("! F@6aJ666a4KJF=K
thermistor leads are considered shorted and the wash tank heaters de-energize, "H1"
appears in the display, and the buzzer sounds.
Z("! !%5aJ%F6a4KJP6<K
thermistor leads are considered open and the wash tank heaters de-energize, "H2" appears
in the display, and the buzzer sounds.
Z*" "
Z !"
HW !
Note: See “III.E. Thermistor Check” and “IV.M. Removal and Replacement of Thermistor.”
Control Board
Defective.
Replace.
Thermistor
Connector not properly
connected.
Reconnect.
Open circuit (H2).
Replace.
Thermistor senses abnormal temperature.
H 1 / H 2
Code Error
Item Possible
Cause
Remedy
Continues (wash tank
heater off).
Operation
Short circuit (H1).
Replace.
Defective.
Replace.
Connector not properly
connected.
Reconnect.