![Hoshizaki JWE-620UA-6B Скачать руководство пользователя страница 33](http://html1.mh-extra.com/html/hoshizaki/jwe-620ua-6b/jwe-620ua-6b_service-manual_2164522033.webp)
28
e) Internal Booster Tank Water Level Error 2 (Internal Booster Tank Water Level Float
Switch Open) (o2)
Z(" ! !
! ! "6
heaters de-energize, "o2" appears in the display, and the buzzer sounds.
Z&" ! !!
the "ON/OFF" button is used to turn the unit off and then back on.
Z !"
Internal booster tank water level float switch is
open and internal booster tank backup water
level switch has remained closed for 1 minute.
o 2
Code Error
Item Possible
Cause
Remedy
Continues (internal
booster tank heater off).
Operation
Defective.
Replace.
Internal Booster Tank
Water Level Float
Switch
Sticking.
Check and clean. See
“
III.D. Float Switch
Check and Cleaning.
”
Open circuit.
Repair or replace.
Control Board
Defective.
Replace.
Connector not properly
connected.
Reconnect.
Defective.
Replace.
Internal Booster Tank
Backup Water Level
Float Switch
Sticking.
Check and clean. See
“
III.D. Float Switch
Check and Cleaning.
”
Note: See “III.D. Float Switch Check and Cleaning.”