B. Cleaning and Sanitizing Instructions
The appliance must be cleaned and sanitized at least once a year. More frequent
cleaning and sanitizing may be required in some water conditions.
WARNING
• To prevent injury to individuals and damage to the appliance, do not use ammonia
type cleaners.
• Carefully follow any instructions provided with the bottles of cleaning and
sanitizing solution.
• Always wear liquid-proof gloves and goggles to prevent the cleaning and sanitizing
solutions from coming into contact with skin or eyes.
NOTICE
To prevent damage to the water pump, do not leave the control switch in
the “WASH” position for extended periods of time when the water tank is
empty
.
1. Cleaning Procedure
1) Dilute approximately 7.2 fl. oz. (214 ml) of recommended cleaner Hoshizaki “Scale
Away” with 0.8 gal. (3.0 l) of water.
2) Turn off the power supply.
3) Remove all ice from the storage bin.
4) Remove the front panel.
5) Remove the screw, then move the water tank drain pipe to the drain position. See Fig. 5.
Use the screw to secure the water tank drain pipe in the drain position.
6) Make sure the control switch is in the “ICE” position, then replace the front panel.
7) Close the icemaker water supply line shut-off valve.
8) Turn on the power supply for 3 minutes. The water tank drains and cubes are removed
from the evaporator.
9) Turn off the power supply.
10) Remove the front panel and top panel.
11) Move the control switch to the “WASH“ position.
12) Slowly pour the cleaning solution over the top of the evaporator and into the water tank.
Do not splash or spill the solution onto other parts.
13) Replace the front panel and top panel in their correct positions.
14) Turn on the power supply to start the washing process.
15) Turn off the power supply after 30 minutes.
16) Open the icemaker water supply line shut-off valve.
17) Remove the front panel.
18) Move the control switch to the "ICE" position.
18