4
ENGLISH
IMPORTANT
Normal operating ambient temperature should be within 1°C to 40°C. Water connection is cold water only. Operation of the
icemaker, for extended periods, outside of these normal temperature ranges may affect production capacity.
Allow the clearance specified below for proper air circulation and ease of maintenance and/or service should they be required.
Side View
Side View
Rear
Front
Top
ICEMAKER
15cm
15cm
Top View
Rear
Front
Left
Right
15cm
15cm
15cm
[Water-cooled model]
[Remote Air-cooled model]
[Air-cooled model]
Rear
Front
Top
ICEMAKER
30cm
30cm
Top View
Rear
ICEMAKER
Front
Left
Right
15cm
50cm
30cm
ICEMAKER
In some high humidity environments, condensation may form inside the machine and drip onto the floor. Do not install where
the floor can be affected by water.
5. INSTALLATION
CAUTION
Incorrect installation can cause harm to people, animals or other items, for which the manufacturer cannot be held
responsible.
1)
Lay the storage bin on its rear side carefully to prevent
damage. Secure the four adjustable legs (bin accessory)
into the four tapped holes on the underside of the bin.
2) Position the storage bin in the selected permanent position,
and level it in both the left-to-right and front-to-rear
directions.
3) Use the screws provided on the left or right side of the
storage bin to install the top kit.
4) Remove the icemaker panels. The rear panel is not required
to be removed for installation. See “3. UNPACKING”.
5) Place the icemaker on the top of the storage bin. Be careful
not to damage the icemaker frame and the bin control
switch.
6) Secure the icemaker to the storage bin at the rear, by using
the mounting brackets and bolts provided.
7) Replace the icemaker panels in their correct position.
Bottom
Adjustable Leg
Adjustable Leg
Top Kit
Icemaker
Mounting
Bracket
Bolt
Bin
Bolt
Mounting
Bracket