B. Performance Data
3UHVVXUHGDWDLVUHFRUGHGDWPLQLQWRIUHH]LQJF\FOH7KHGDWDQRWLQEROG
VKRXOGEHXVHGIRUUHIHUHQFHRQO\
1. IM-200BAA
70/21
91
188
85
176
80
80/27
191
87
173
78
163
74
90/32
188
85
73
149
68
lbs./day kg./day
100/38
187
85
157
71
63
70/21
80/27
90/32
watts
100/38
70/21
0.18
44
0.16
41
0.15
80/27
44
0.17
40
0.15
37
0.14
90/32
44
0.16
0.14
34
0.13
gal./day m
3
/day
100/38
40
0.15
36
0.14
0.12
70/21
80/27
90/32
min.
100/38
70/21
80/27
90/32
min.
100/38
70/21
7.5
120
8.4
135
9.5
80/27
117
8.2
137
9.6
150
10.5
90/32
120
8.4
10.6
165
11.6
PSIG kg/cm
2
G
100/38
122
8.6
154
10.8
12.5
70/21
0.7
11
0.7
11
0.8
80/27
10
0.7
11
0.8
12
0.8
90/32
11
0.7
0.8
13
0.9
PSIG kg/cm
2
G
100/38
11
0.7
12
0.9
0.9
28
28
31
1.5
2.2
2.9
2.1
3.1
APPROXIMATE ICE
PRODUCTION PER 24 HR.
APPROXIMATE ELECTRIC
CONSUMPTION
APPROXIMATE WATER
CONSUMPTION PER 24 HR.
FREEZING CYCLE TIME
WATER TEMP. (ºF/ºC)
AMBIENT TEMP.
(ºF/ºC)
50/10
70/21
90/32
38
517
515
534
554
511
515
35
28
29
531
548
566
32
36
SUCTION PRESSURE
HARVEST CYCLE TIME
HEAD PRESSURE
2.0
2.0
2.9
1.3
TOTAL HEAT OF REJECTION FROM CONDENSER
3,500 BTU/h [AT 90ºF (32ºC) / WT 70ºF (21ºC)]
TOTAL HEAT OF REJECTION FROM COMPRESSOR
660 BTU/h [AT 90ºF (32ºC) / WT 70ºF (21ºC)]