2. Condenser Fan Motor
1) Open the front panel. Move the power switch to the "OFF" position, then unplug the
unit.
2) Remove the left side panel.
3) Disconnect the fan motor wires.
4) Remove the condenser fan motor assembly bolts, then remove the condenser fan
motor assembly. See Fig. 10.
5) Remove the fan motor from the fan motor bracket and remove the fan blade from the
fan motor.
6) Place the fan blade on the new fan motor, then install the new fan motor.
7) Replace the fan motor assembly in its correct position.
8) Connect the fan motor wires.
9) Replace the panels in their correct positions.
10) Plug in the unit, then move the power switch to the "ON" position to start the unit's
cooling process.
Condenser Fan
Motor Bracket
Condenser Fan Motor
Condenser Fan Blade
Condenser
Fig. 10
3. Rail Fan Motor
1) Open the front panel. Move the power switch to the "OFF" position, then unplug the
unit.
2) Remove the storage pans from the rail area. If wet, dry the rail area with a dry cloth.
3) Remove the rail fan motor shroud. See Fig. 11.
4) Disconnect the rail fan motor lead wires at least 6" (15 cm) from the fan motor. Remove
the rail fan motor and bracket.
5) Remove the rail fan motor bracket from the old rail fan motor and place on the new rail
fan motor.
6) Secure the new fan motor wires to the old fan motor wires in the rail area. DO NOT cut
the new fan motor wires.