20
13) Clean the storage bin liner using a neutral cleaner. Rinse thoroughly after cleaning.
14) Reconnect the bin control connector.
15) Plug the icemaker back in. Move the control switch to the "ICE" position to start the
automatic icemaking process.
16) To confirm bin control operation, press and hold the bin control's actuator paddle during
the first 5 minutes of the freeze cycle. The icemaker should shut down in approximately
5 seconds.
17) Replace the bin cover in its correct position.
18) Reconnect the connector from the front panel to the control box and replace the front
panel in its correct position.
19) On water-cooled model, confirm proper condenser drain outlet/return outlet
temperature as outlined in "II.F.2. Water-Cooled Condenser."
Содержание DKM-500BAH
Страница 7: ...7 B Dimensions Connections 1 DKM 500BAH Unit mm in...
Страница 8: ...8 2 DKM 500BWH Unit mm in...
Страница 29: ......
Страница 30: ......
Страница 31: ......