19
H. Startup
WARNING
All parts are factory-adjusted. Improper adjustments may adversely affect safety,
performance, component life, and warranty coverage.
NOTICE
• If the icemaker is turned off, wait for at least 3 minutes before restarting the
icemaker to prevent damage to the compressor.
• The pump motor is energized continuously when the control switch is in the
"SERVICE" position.
• At startup, confirm that all internal and external connections are free of leaks.
1) Open the water supply line shut-off valve(s).
2) Remove the front panel and disconnect the connector from the control box (if the front
panel is not already removed).
3) Make sure the control switch on the control box is in the "OFF" position, then plug the
icemaker into the electrical outlet.
4) Move the control switch to the "ICE" position.
5) Replace the front panel in its correct position.
6) Allow the icemaker to operate for 5 minutes to fill the water tank.
7) Remove the front panel, then move the service switch to the "WASH" position. Move the
control switch to the "SERVICE" position.
8) Replace the front panel in its correct position and allow the icemaker to run for
5 minutes.
9) Remove the front panel, then move the service switch to the "DRAIN" position.
10) Replace the front panel in its correct position and allow the icemaker to drain for
2 minutes.
11) Remove the front panel, then move the control switch to the "OFF" position. Unplug the
icemaker from the electrical outlet.
12) Disconnect the bin control connector. See Fig. 6. Remove the 3 thumbscrews securing
the bin cover, then remove the bin cover with the bin control attached.
Thumbscrew
Bin Cover
Bin
Control
Connector
Storage Bin
Fig. 6
Bin Control
Actuator Paddle
Содержание DKM-500BAH
Страница 7: ...7 B Dimensions Connections 1 DKM 500BAH Unit mm in...
Страница 8: ...8 2 DKM 500BWH Unit mm in...
Страница 29: ......
Страница 30: ......
Страница 31: ......