![Hoshizaki DIM-30DE-2 Скачать руководство пользователя страница 30](http://html1.mh-extra.com/html/hoshizaki/dim-30de-2/dim-30de-2_service-manual_2165045030.webp)
26
Maintenance Mode Settings
No
Item
DIM-30DE-2
Tin plated
Electroless
nickel plated
Basic
1 Defrost completion temp
5
5
2 Integrated constant 1 (temp)
-16.5
-17
3 Integrated constant 2 (time)
14
14
4 Ambient temp correction operating temp
for integrated value
38
38
5 Ambient temp correction rate for integrated
value
75
75
6
Freeze backup timer
45
45
Water supply
10 Defrosting water supply time, water temp
less than 13°C
15
15
11 Defrosting water supply time, water temp
13°C or more
6
6
12 Icemaking water supply time
20
20
13 Water temp measurement correction value
7
10
14
Full / partial drain flush selection
0
0
15 Additional icemaking water supply time
0
0
17 Defrosting water control
0
0
18 Defrost completion temp correction
0
0
Other
21 Double stack bin control
1
1
22 Refrigeration unit operation in bin control
cycle
0
0
Model
30 Type
1
1
Defrost cycle
low temp control
34 Operating temp
45
45
Water regulator 36 Water regulator error detecting temp
0
0
Compressor
37 Compressor output selection
0
0
Slush ice
50
Pump off time
30
90
51 Water supply time
0
0
Hard water
60 Operating condition
10
10
61 Water supply time
0
0
Ice left in water
pan
70 Operating temp
23
47
71 Hot gas valve on time
10
10
72
Hot gas valve off time
20
20
Ice bridge
73
Hot gas valve off time
0
0
Low temp in
defrost cycle
74 Operating temp
15
15