13
U07
Sold out sensor
setting
0: Setting A (mainly beer) / threshold: 2.2V
1: Setting B (mainly cocktail) / threshold: 2.5V
2: Setting C (mainly cocktail) / threshold: 2.8V
3: Setting D (optional) / threshold: optional
* The setting depends on the brand of beverage to dispense.
Check with your dealer/supplier.
0
0 to 3
U08
Self mode
setting
0: No
1: Yes (no button operation is available except
dispense/stop button)
* The self mode is reset when the manual dispensing mode is
selected (by lifting up the operation panel unit). To resume
the self mode, switch to the automatic dispensing mode (by
pulling down the operation panel unit) and press the dispense
button.
0
0 to 1
U09
Mug tilting
operation
0: Yes (mug is tilted while beer is being dispensed)
1: No (mug is kept upright while beer is being dispensed)
0
0 to 1
U10
Reset number
of mugs
0: Manual
1: Manual or when sold out sensor detects
* To reset manually, press and hold the stop button for 3
seconds.
0
0 to 1
U90 Reset settings
Initialize only the user settings
* To initialize, with “1” shown on the display, press and hold the
stop button for 3 seconds.
* If the settings are updated, “U90” appears on the display. If
not updated, “0” appears again.
0
0 to 1
*1: When “U10” is set to “1”, only the current log will be reset.
*2: When “U10” is set to “1”, only the number of sold out will be counted. The number of 3-second
stop button operation with the number of mugs or “U02” on the display will not be counted.