Hoshizaki DBF-25SB-AU Скачать руководство пользователя страница 4

3

IMPORTANT

1. Cut  the  beer  hose  with  a  specialized  tool  such  as  hose 

cutter. Do not use scissors, or the beer hose may be crushed 

to cause beer leaks.

2. Do not disconnect and reinsert the beer hose. Cut it about 

20 mm before reuse.

3. Cut the hose end vertically, insert it securely into the quick 

joints, and check for beer leaks.

5. TRIAL RUN

[a] COOLING WATER SUPPLY

IMPORTANT

When filling the water tank, be careful not to splash water onto 

the electrical parts. 

1) Check that the unit is unplugged.

2) Remove the top cover and inner cover.

3) 

[DBF-25SB-AU]

 

Fill the water tank with tap water. The water tank overflows when 

the water level reaches about 2 cm below the top of the water tank. 

Then stop pouring water.

 

[DBF-43SB-AU]

 

Fill  the  water  tank  with  tap  water  up  to  the  standard  water  level 

marked on the tank. 

[b] PRESSURE RANGE

Adjust the CO2 gas pressure to the following range (reference).

Beer keg temperature

Gas pressure

10°C

0.15 - 0.20 MPa (scale 1.5 - 2.0)

20°C

0.22 - 0.25 MPa (scale 2.2 - 2.5)

30°C

0.32 - 0.35 MPa (scale 3.2 - 3.5)

*  The appropriate keg pressure depends on the type and temperature 

of  beer. Adjust  the  gas  pressure  according  to  the  beer  company’s 

instructions. Insufficient pressure may result in excessive foaming.

[c] EXTERNAL CO2 GAS LINE

1) Determine the positions of the CO2 gas cylinder and beer keg to 

make the gas hose length within 1.4 m.

2) Cut the gas hose to have a vertical cutting plane.

3) Insert  the  gas  hose  into  the  quick  joints  on  the  keg  coupler  and 

regulator. Pull the hose hard to check for tight connections.

4) Use the adjust dial to check for gas leaks.

IMPORTANT

1. Cut the gas hose with a specialized tool such as hose cutter. 

Do  not  use  scissors,  or  the  gas  hose  may  be  crushed  to 

cause gas leaks.

2. Do not disconnect and reinsert the gas hose. Cut it about 20 

mm before reuse.

3. Cut the hose end vertically, insert it securely into the quick 

joints, and check for gas leaks.

Quick gas hose joint

1) To insert the gas hose into the quick joint, push it all the way in.

2) To disconnect the gas hose from the quick joint, push it with fingers 

as shown below and pull it out.

Quick joint

Gas hose

[d] EXTERNAL BEER LINE

1) Attach  the  O-ring  P10A  (accessory)  on  the  beer  hose  adapter 

(accessory), and install it on the beer inlet.

2) Attach  the  beer  hose  joint  specified  by  the  beer  company  on  the 

beer hose adapter.

3) Determine  the  positions  of  the  beer  hose  joint  and  beer  keg  to 

make the beer hose length within 2.1 m.

4) Cut the beer hose to have a vertical cutting plane.

5) Insert  the  beer  hose  into  the  quick  joints  on  the  keg  coupler 

and  quick  beer  hose  joint.  Pull  the  hose  hard  to  check  for  tight 

connections.

Water level at installation

4) Refit the inner cover and top cover.

5) Plug in the unit.

[b] CHECKS AFTER INSTALLATION

*  Normal  operating  ambient  temperature  should  be  within  5°C  to 

35°C,  and  cooling  water  temperature  within  5°C  to  30°C.  Do  not 

install  the  unit  where  it  could  freeze.  Operation  outside  of  these 

normal temperature ranges may affect performance.

*  Be  sure  to  use  tap  water  with  a  turbidity  level  of  not  more  than 

2.  Use  of  well  water  or  other  non-tap  water  or  mixture  with  salt, 

vinegar,  or  juice  may  cause  inadequate  ice  storage,  corrosion,  or 

holes.

*  The  beer  circuit  has  been  cleaned  before  shipping.  But  clean  it 

again before starting up the unit, and check for proper installation of 

each part.

*  Check the power cord and hoses before starting up the unit.

IMPORTANT

1. Do  not  install  the  unit  where  exposed  to  humidity  or  water 

splashes.

2. Do not remove the top cover or carry the unit with wet hands.

3. Be sure to unplug the unit before removing the top cover for 

cleaning or inspection.

4. Do not attempt to disassemble, repair, or modify the unit.

Содержание DBF-25SB-AU

Страница 1: ...DRAFT BEER DISPENSER DBF 25SB AU DBF 43SB AU INSTRUCTION MANUAL L168QU111 062012 ...

Страница 2: ... pcs Chain 1 pc Beer hose adaptor 1 pc Drain pan 1 pc Drain board 1 pc Nozzle cap 3 pcs O ring P10A 1 pc O ring P21 1 pc 2 UNPACKING AND LOCATION CAUTION 1 To prevent injury wear work gloves and hold the bottom panel to carry the unit Work in a pair or group 2 The location should provide a firm and level foundation for the equipment to avoid the risk of water leaks or injury caused by overturn or ...

Страница 3: ...ontains CO2 gas to prevent beer from becoming flat and to push beer out of the keg Consult with the liquor shop or beer company and prepare a proper CO2 gas cylinder intended for use with beer 9 Cylinder chain accessory Securely retain the CO2 gas cylinder on the fixed hook 10 Hook accessory Mount on a firm base with the screws provided 11 Regulator Adjusts CO2 gas pressure in the cylinder for pro...

Страница 4: ...nect and reinsert the gas hose Cut it about 20 mm before reuse 3 Cut the hose end vertically insert it securely into the quick joints and check for gas leaks Quick gas hose joint 1 To insert the gas hose into the quick joint push it all the way in 2 To disconnect the gas hose from the quick joint push it with fingers as shown below and pull it out Quick joint Gas hose d EXTERNAL BEER LINE 1 Attach...

Страница 5: ...ANT 1 Wash the keg joint with water if necessary 2 Do not loosen the ferrule on the keg 5 Turn the regulator adjust dial clockwise to the appropriate gas pressure level specified by the beer company 4 Attach the keg coupler on the new keg by turning it clockwise Keg coupler handle Rotary type Vertical type Regulator Adjust dial Keg coupler Keg Rotary type Vertical type Regulator Adjust dial Keg co...

Страница 6: ... nozzle end Wash the nozzle cap clean and fit it on the nozzle The nozzle cap must be removed and stored in a clean place during operation Fit on Beer tap Nozzle Nozzle cap 1 Tilt a clean mug at an angle of 45 and place its inner surface in contact with the liquid nozzle of the beer tap 2 Pull the beer tap lever toward you to dispense beer over the inner surface of the mug 3 After dispensing a spe...

Страница 7: ...coupler handle clockwise until it stops Vertical type Push down the keg coupler handle until it locks in place 12 Check if the cleaning tank is provided with a siphon tube inside If no siphon tube is provided Turn down the ferrule of the cleaning tank upside down If siphon tube is provided Turn up the ferrule of the cleaning tank 13 Prepare a plastic bucket to receive cleaning water Move the beer ...

Страница 8: ...ter 3 Lift the drain pan to hook the mounting holes on the mounting screws and set the drain board on the drain pan 4 Check that the overflow hose goes through the hole in the drain board and can drain water into the drain pan Mounting screw Through hole for overflow hose Mounting hole Overflow hose Drain board Drain pan 4 CLEANING BEER CIRCUIT WITH SPONGE WEEKLY IMPORTANT 1 Store the used cleanin...

Страница 9: ...ning tank 22 Attach the keg coupler on the keg Keg coupler handle Rotary type Vertical type Keg coupler Rotary type Vertical type Cleaning tank 19 Recover the cleaning sponge from the bucket 20 Repeat the above steps 10 to 16 until clear water comes out of the beer tap 21 Remove the beer tap set the valve shaft in its normal position and refit the beer tap on the unit Keg coupler Keg Rotary type V...

Страница 10: ...d you Push it down and pull it out 3 Wash the air filter with cold water or warm water containing a neutral dishwashing detergent Be careful not to break the net After using a detergent rinse the air filter thoroughly Dry it in the shade Drain pan Air filter 4 Fit the air filter into the filter guide at the bottom and slide it to the back 5 Refit the drain pan IMPORTANT 1 When the air filter is cl...

Страница 11: ...er tank according to I 5 a COOLING WATER SUPPLY 7 Refit the top cover and inner cover 8 Plug in the unit IMPORTANT Dust bacteria and moisture in the air may cause contamination or reduction in conductivity of the cooling water To prevent clogging of the overflow hose or inadequate ice storage refresh the cooling water twice a year If the cooling water conductivity reduces and no ice is produced in...

Отзывы: