10
2. Do not damage the power cord. It should not be additionally
processed, jerked, bundled, weighed down or caught in. It
could cause electric shock or fire.
3. The unit must have a separate power supply. Branching off
the power cord, using an extension cord, or sharing a single
power supply with other appliances may result in electric
shock, heat generation or fire.
Check that:
* The attachment plug blades and their vicinity and the receptacle are
free of dust. Clean them if necessary.
* The attachment plug and power cord are not damaged, weighed
down or caught in.
* The attachment plug is plugged into a separate receptacle.
3. COOLING WATER (BIANNUALLY)
1) Unplug the unit.
2) Remove the top cover and inner cover.
3) Check that the cooling water level is about 2 cm below the top of
the water tank (DBF-25SB-AU) or up to the standard water level
marked on the tank (DBF-43SB-AU). If it is insufficient, refill the
water tank with tap water. Refresh the cooling water twice a year.
To refresh the cooling water:
4) Remove the drain pan.
5) Prepare a large container to receive drain water [about 6 L (DBF-
25SB-AU) or 8 L (DBF-43SB-AU) in ice storage]. Remove the drain
plug, and drain the water tank. After the cooling water has drained
out, refit the drain plug.
6) Refill the water tank according to “I. 5. [a] COOLING WATER
SUPPLY”.
7) Refit the top cover and inner cover.
8) Plug in the unit.
IMPORTANT
Dust, bacteria, and moisture in the air may cause contamination
or reduction in conductivity of the cooling water. To prevent
clogging of the overflow hose or inadequate ice storage, refresh
the cooling water twice a year.
If the cooling water conductivity reduces and no ice is produced
in the water tank, fill 1/3 (2 g) of the nozzle cap with baking
soda. Do not use an excessive amount of baking soda or any
other substances such as salt, vinegar, and juice. They will
corrode the stainless steel and copper tubes and cause failure.
1/3 (2 g)
Nozzle cap (accessory)
V. LONG STORAGE, RELOCATION, DISPOSAL,
TRANSFER
* When shutting down the unit for more than a week, carry out the
following maintenance procedures to clean and drain the beer
circuit and to keep the unit clean:
III. 4. CLEANING BEER CIRCUIT WITH SPONGE
5. DISASSEMBLY AND CLEANING OF BEER TAP
6. KEG COUPLER
7. EXTERIOR
8. AIR FILTER
Drain the water tank according to “IV. 4. COOLING WATER”. It
takes a few days to melt ice left in the water tank. After melting all
the ice, drain the water tank again, and dry the tank interior.
* In case of relocation or disposal of the product, contact an
authorized Hoshizaki service company.
* When selling or transferring this product, tape this instruction
manual to the exterior to provide the new owner with information on