26
F. Water Supply and Drain Connections
WARNING
Water supply and drain connections must be installed in accordance with applicable
national, state, and local regulations.
NOTICE
• Normal operating water temperature must be within 45°F to 95°F (7°C to
35°C). Operation of the icemaker, for extended periods, outside of this normal
temperature range may affect icemaker performance.
• To prevent damage to the icemaker, do not operate the icemaker when the water
supply is off, or if the pressure is below 10 PSIG. Do not run the icemaker until the
proper water pressure is reached.
• Connect to potable water supply only. Do not connect to a hot-water supply.
• In areas where water damage is a concern, install in a contained area with a floor
drain.
• Water line installation to the icemaker is not warranted by Hoshizaki.
• Water-hammer issues must be resolved by a qualified plumber before installing
the icemaker. Water hammer can cause icemaker damage that may lead to water
leakage or flooding.
• If using the optional drain pump (HS-5061), test its operation every time the
icemaker is cleaned and sanitized. See "IV.E. Optional Drain Pump HS-5061" for
details. If the optional drain pump is not operating properly, water could back up
and overflow, leading to costly water damage.
• A plumbing permit and services of a licensed plumber may be required in some areas.
• External filters, strainers, or softeners may be required depending on water quality.
Contact your local Hoshizaki Certified Service Representative for recommendations.
• Water supply inlet is 1/2" female pipe thread (FPT).
Fig. 31
Water Supply Line
Shut-Off Valve
Water Supply Line
Drain Valve
Water Supply Inlet
1/2" FPT
Drain Outlet
1/2" FPT
Piping to approved drain. Leave a
2-inch (5-cm) vertical air gap between
the end of the pipe and the drain.
2-inch (5-cm)
air gap
Floor
Drain
Vented Tee Connection
Extend the vent at least
12" (30 cm) above the
drain outlet.
Minimum 1/4" Nominal ID
Copper Water Tubing or
Equivalent
Minimum 1/2"
Nominal ID Hard Pipe
or Equivalent