52
GENERAL INSTRUCTIONS
WARNING
Switch the stove off and let it cool down at room temperature before carrying out
maintenance. Wait for at least an hour after shutting down the device.
WARNING
Always use anti-heat gloves to avoid possible skin burns.
WARNING
Deactivate the back switch by moving it to “0” (figure 1) Unplug the device.
WARNING
Do not unplug the device or deactivate the back switch by moving it to "0" when the stove is on. This will
block all the engines in the device and hamper the exhaustion of fumes inside the stove.
WARNING
In case of flue fire, unplug the device, do not open any compartment and immediately contact the fire
department.
MAINTENANCE BY YOUR SERVICE RETAILER (LOCAL AUTHORIZED RETAILER)
WARNING
Extraordinary maintenance must be performed by your Service Retailer.
WARNING
Before any type of maintenance, replacing, repairing, cleaning, etc. make sure your stove has no connection
whatsoever to energy power supplies (disconnect the power supply cable from its socket)
Wear safety devices (e.g. anti-perforation gloves) when carrying out maintenance operations. Carry out maintenance
when the stove is shut down and completely cooled off.
OPERATIONS TO BE CARRIED OUT EVERY YEAR BY YOUR SERVICE RETAILER (Local
Authorized Retailer)
-
General internal and external cleaning.
-
Accurate cleaning of exchanging pipes.
-
Carbon-removal and accurate cleaning of the brazier and the brazier compartment.
-
Cleaning of engines, mechanical check of clearances and fixtures.
-
Cleaning of fume pipes (replacement of pipe gaskets) and of the fume exhaustion compartment.
-
Cleaning of the pressure switch, replacement of the small silicon tube.
-
Probe check Carbon-removal, cleaning and checking of the ignition resistance compartment, replacing it if necessary.
-
Visual match of electrical cables, connections and power supply cable.
-
Cleaning of pellet tank and checking of clearances and auger/geared motor.
-
Functional test, loading of the auger, ignition, operating the stove for 10 minutes, switching off.
-
Check of electrical parts and all electronic devices.
RECOMMENDATIONS FOR TECHNICIANS
The device must be installed by qualified and trained staff who is aware of the requirements set forth by UNI EN 14785 2006 and
other installation-related regulations.
Содержание AQUA 14.0
Страница 32: ...32...
Страница 33: ...33 PELLET STOVE OPERATING INSTALLATION AND MAINTENANCE MANUAL MOD AQUA PURO 14 0 18 5 EN...
Страница 46: ...46...
Страница 57: ...57 PO LE GRANUL S AQUA PURO GUIDE D INSTALLATION D UTILISATION ET D ENTRETIEN MOD AQUA PURO 14 0 18 5 FR...
Страница 72: ...72...
Страница 80: ...80...
Страница 81: ...81 PELLETKACHEL AQUA PURO INSTALLATIE GEBRUIKS EN ONDERHOUDSHANDLEIDING MOD AQUA PURO 14 0 18 5 NL...
Страница 103: ...103...