3. Apply O-ring lubricant to the outside O-rings of the new Car-
tridge and install the new Cartridge Assembly into the Journal
Bracket; then, reinstall the Retaining Rings to hold the new
Cartridge Assembly in tight.
The Retaining Ring must be fully seated in the retaining ring
groove to keep the Cartridge Assembly from moving. Also, the
Retaining Ring is beveled. The curved side must be installed
facing the Cartridge.
4. Clean both the Carbon Tip of the Cartridge Assembly and also
the Face Seal of the Air Chamber Assembly to make sure they
are free of lubricants and dust.
CAUTION
14