CHAPTER 1:  SAFETY / COMPLIANCE 

 

1.1 

Safety Warnings and Guidelines 

 
When found on the product, the following symbols specify:  
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 

  All applicable codes and standards need to be followed in the installation of this product. 

  For I/O wiring (discrete), use the following wire type or equivalent:  Belden 9918, 18 AWG 

or larger.  

 
Adhere to the following safety precautions whenever any type of connection is made to the 
module.  
 

  Connect the green safety (earth) ground first before making any other connections.  

  When connecting to electric circuits or pulse-initiating equipment, open their related 

breakers.  Do not make connections to live power lines.    

  Make connections to the module first; then connect to the circuit to be monitored.   

  Route power wires in a safe manner in accordance with good practice and local codes. 

  Wear proper personal protective equipment including safety glasses and insulated gloves 

when making connections to power circuits.  

  Ensure hands, shoes, and floor are dry before making any connection to a power line.  

 Warning:

  Consult user documentation. 

Warning:

  Electrical Shock Hazard.

 

WARNING:  This equipment is approved only for mobile and base station transmitting devices. 
Antenna(s) used for this transmitter must be installed to provide a separation distance of at 
least 30 cm from all persons and must not be co-located or operating in conjunction with any 
other antenna or transmitter.  
 
NOTE: The separation distance indicated in the above is 30 cm, but any distance greater than 
or equal to 23 cm can be used (per MPE evaluation). 
 
WARNING:  To avoid the risk of electric shock or burns, always connect the safety (or earth) 
ground before making any other connections.  

 

WARNING:  To reduce the risk of fire, electrical shock, or physical injury it is strongly 
recommended to fuse the voltage measurement inputs.  Be sure to locate fuses as close to the 
source as possible. 

 

WARNING:  Replace fuse with the same type and rating to provide protection against risk of 
fire and shock hazards.   

 

WARNING:  In the event of repeated failure, do not replace the fuse again as a repeated failure 
indicates a defective condition that will not clear by replacing the fuse.  

 

WARNING:  Only qualified electrical personnel familiar with the construction and operation of 
this equipment and the hazards involved should install, adjust, operate, or service this 
equipment.  Read and understand this manual and other applicable manuals in their entirety 
before proceeding.  Failure to observe this precaution could result in severe bodily injury or 
loss of life. 

Содержание HE-XRZ2

Страница 1: ...Manual for HE XRZ2 2 4GHz Modem COM Module ...

Страница 2: ...PAGE 2 19 MAR 2007 MAN0943 01 MAN0943 01 ...

Страница 3: ...d in this document or media is also copyrighted material subject to the terms and conditions of the Horner Software License Agreement Information in this document is subject to change without notice and does not represent a commitment on the part of Horner APG Cscape SmartStack SmartStix and CsCAN are trademarks of Horner APG Ethernet is a trademark of Xerox Corporation Micro SD and CompactFlash a...

Страница 4: ...OM Module IS ORIGINALLY INSTALLED THIS WARRANTY SHALL APPLY ONLY WITHIN THE BOUNDARIES OF THE CONTINENTAL UNITED STATES In no event whether as a result of breach of contract warranty tort including negligence or otherwise shall HE APG or its suppliers be liable of any special consequential incidental or penal damages including but not limited to loss of profit or revenues loss of use of the produc...

Страница 5: ...ABILITY 4 CHAPTER 1 SAFETY COMPLIANCE 6 1 1 Safety Warnings and Guidelines 6 CHAPTER 2 INTRODUCTION 8 2 1 Overview 8 2 2 Technical Support Contacts 8 CHAPTER 3 INSTALLATION PROCEDURE 9 3 1 Installation Procedure 9 CHAPTER 4 OPERATION 10 4 1 Configuration 10 4 2 Ladder communications 10 ...

Страница 6: ...tion transmitting devices Antenna s used for this transmitter must be installed to provide a separation distance of at least 30 cm from all persons and must not be co located or operating in conjunction with any other antenna or transmitter NOTE The separation distance indicated in the above is 30 cm but any distance greater than or equal to 23 cm can be used per MPE evaluation WARNING To avoid th...

Страница 7: ...ransmitter including antenna gain and cable loss must not exceed the EIRP of the configuration used for calculating MPE Grantee MaxStream must coordinate with OEM integrators to ensure the end users and installers of products operating with the module are provided with operating instructions to satisfy RF exposure requirements The FCC grant is valid only when the device is sold to OEM integrators ...

Страница 8: ...and to exit command mode is issued thereafter either the SEND RECV or MODBUS function blocks may be then used to transfer data The HE XRZ2 utilizes the same internal communications channel UART as the MJ1 serial port thus enabling the HE XRZ2 deactivates the MJ1 serial port However support is provided to select which device is currently active through ladder control The HE XRZ2 is provided connect...

Страница 9: ...sure all the pins are properly aligned Figure 2 4 Place the extended back cover onto the unit It can be helpful to tip it at an angle so the connector on the COM board passes through the opening on the back cover 5 Place the screw back into the hole and turn the screw slowly counter clockwise until it clicks into the threads This prevents the screw from being cross threaded Now turn the screw cloc...

Страница 10: ... the I O Configuration dialog by clicking the OK button the application is configured for the HE XRZ2 Failure to set HEXRZ2 in the I O Configuration when attempting to download an application that uses an OPEN function block set to Radio generates a download error Even if the HE XRZ2 is not used by the application the HEXRZ2 must still be set in the I O Configuration to prevent an I O Configuratio...

Страница 11: ...mmands and corresponding transmit modes are covered in detail in the MaxStream XBEE Pro OEM RF Module Product Manual available at http www maxstream net products xtend product manual_XTend_OEM_RF Module pdf When transferring data handshaking is generally not required for messages less than 2K bytes The HE XRZ2 breaks larger messages into smaller packets for transfer between HE XRZ2 modems Note tha...

Отзывы: